damian LXS9 Series Скачать руководство пользователя страница 37

 

Serie "LXS9"

 

 
 

 

Pagina A - 15 

 

Rev. M - 01 

 

EVA-DTS PARAMETERS 

P

ASSWORD CODE RESET 

(EVA-DTS): 

To  reset 

the  “Security”  and  “Passcode”  codes  foreseen  by  the  DDCMP  protocol  (EVA-DTS)  to  prevent 

anyone from being able to access and download the data relative to the vending machine proceeds using 
an IRDA handheld device. 
 
 
 
 
 
 
 
Thanks  to these  protection  codes,  the  data can  be  downloaded  only  if  those  set on  the  handheld  device 
coincide with those acquired previously by the vending machine. 
If the 2 codes do not correspond, the following error message will appear: 
 
 
 
 
In this case, the codes acquired by the vending machine must be reset (Reset Passcode) by entering the 
password. 
At this point the vending machine has no protection code and will reacquire a new one at the time of the 
next connection with a handheld device that has a code other than 0 set . 

 

AUDIT PARAMETERS 

NOTE:

 It is possible to display a minimum list of sales data on the automatic vending machine. If an MDB 

system is installed, the vending machine collects more detailed data, available in the EVA-DTS format. 
 

P

ARTIAL COUNTER OF NUMBER OF VENDING MACHINE SALES

To read the total number of vending machine sales since the last reset. 

 

 
 
 
 
 

P

ARTIAL COUNTER OF VALUE OF VENDING MACHINE SALES

To read the total amount collected by the vending machine since the last reset.  

 

 
 
 
 
 

» 

C

OUNTER OF NUMBER OF SALES PER SELECTION

To read the total (absolute and partial since the last reset) number of sales for each individual vending 
machine selection. 

 

 

 

 

DDCMP error 

9071 

 

Programming 
EVA DTS param. 

 

 

Reset Passcode 

->->->

 

 

Password 

00000

 

 

Programming 
Audit data 

 

Partial n. sales 

Current value

 

 

Programming 
Audit data 

 

Part.Val.Sales 

Current value

 

 

Programming 
Audit data 

 

 

Num.Sales Motors 

->->->

 

 

Motor :   xx 

P xxxxx  T xxxxx

 

 

Содержание LXS9 Series

Страница 1: ...X INSTALLATION AND SERVICE PROGRAMMING This manual is for skilled service personnel only DAMIAN S R L VIA RAGAZZI DEL 99 N 30 21053 CASTELLANZA VA ITALY Rev M 01 Vers Software 1 1a or follow...

Страница 2: ...Serie LXS9 Pagina A 25 Rev M 01...

Страница 3: ...ed use for LXS9 series LUCE X SNAC automatic spiral vending machines consists of automatically distributing solid products or products in solid package pre packaged foods snacks bottled drinks etc and...

Страница 4: ...stem version Absent Super Minimum internal operating temperature 2 C Food zone only Environment Storage temperature 0 45 C Working temperature 5 32 C Max relative humidity 65 Dimensions and Weights He...

Страница 5: ...hildren should be supervised to make sure that they do not play with the vending machine Before checking any electrical part move the main switch of the vending machine See Figure 2 to the OFF positio...

Страница 6: ...them rest correctly on the ground When the vending machine is not levelled properly it can be difficult to close the door With the wall anchoring bracket kit accessory it is possible to anchor the ve...

Страница 7: ...d service personnel Before all operations on the power cord make sure that the power supply plug is disconnected from its outlet Remove the rear grille of the cabinet by unscrewing its fixing screws r...

Страница 8: ...ation of the executive payment systems Connect the Molex 15 pin female power connector of the vending machine to the corresponding connector on the payment system Refer to the payment system documenta...

Страница 9: ...iding panel motor 18 Sliding panel motor pinion 5 Two magnets for locking the Push door 12 Door open switch 6 Two microswitches of the Push locking magnets 13 Two beginning end stroke microswitches 19...

Страница 10: ...time B is prolonged by a value equal to the one set in the Restocking time C parameter Each time it is turned back on if the internal temperature exceeds the Safety temperature A but the conditions f...

Страница 11: ...probe has been replaced the problem is repeated the fault might be due to the CLP1 power board located in the electrical box OFF L02 Temperature probe 2 error These messages indicate a problem with th...

Страница 12: ...Sliding door test as explained further on OFF L12a Door Push EMagnet Fault Magnets for locking the Push door short circuited One or both magnets 5 for locking the door are short circuited Check their...

Страница 13: ...fter maintenance Check that the panel motor 11 power supply connection has not been inverted OFF L13e TimeOut SD Mot Sliding panel error during opening At the end of an opening cycle the sliding panel...

Страница 14: ...gnostic tests some motor anomaly messages might appear on the display these messages are listed below with the relative explanation as well as some possible solutions to the problem Motor xx Disconnec...

Страница 15: ...LAYED During normal vending machine operation some malfunctions of some motors may occur These malfunctions generate errors that can be automatically reset by the vending machine R or that can be not...

Страница 16: ...motors function is not activated If the problem persists make sure that the CPU card works and replace it if necessary THE MACHINE DOES NOT REACH THE REQUIRED TEMPERATURE Before carrying out any oper...

Страница 17: ...and disconnect the power supply wiring of the refrigerator from the electrical box Grasp the handle e at the base of the refrigeration unit and remove it from the normal work position by pulling it if...

Страница 18: ...te B F2 5x20 T6 3 6 3 A delayed 250 V General 24 28V The vending machine does not work C F3 5x20 T6 3 6 3 A delayed 250 V General 230V The vending machine does not work D F4 5x20 T6 3 6 3 A delayed 25...

Страница 19: ...that it turns on again only after it has been closed completely SLIDING PANEL CHECK AND LUBRICATION Sliding panel 10 operation can be checked by performing a door closing and opening test see programm...

Страница 20: ...roswitches and that the magnets can move freely After having reassembled the magnet covering panel perform a door closing and opening test see programm diagnostics Product door test CHECK CLEANING OF...

Страница 21: ...nctions provided for by the regulations in force 1 In the European Union If the equipment is marked on the outside with this symbol it should not be disposed of with normal household waste Contact you...

Страница 22: ...Serie LXS9 Page 21 Rev M 01...

Страница 23: ...tachment A PROGRAMMING SHEET This attachment is an integral part of the manual and must remain with it DAMIAN S R L VIA RAGAZZI DEL 99 N 30 21053 CASTELLANZA VA ITALY Rev M 01 Vers Software 1 1a or fo...

Страница 24: ...ain from the first parameter When the message relative to the desired parameter appears press the F Enter key to confirm TO CHANGE THE PROGRAMMED VALUE OF THE SELECTED PARAMETER If appears on the seco...

Страница 25: ...ght Kit installed Energy Saving allows activating two separate energy saving functions Save Mode function Kicks in after a programmed vending machine inactivity time and reduces the electrical consump...

Страница 26: ...Vivilight Kit installed This parameter allows setting the luminous intensity in of the LED lamps that light up the display window when the Night Mode function is activated Settable values 0 100 Defaul...

Страница 27: ...il or if the 3 step function is not active the vending machine still keeps the credit stored in memory and allows a new selection to be made When this function is selected it will be possible to set t...

Страница 28: ...appears on the display after selecting the desired language press F to confirm B This message appears on the display Check that the number of connected motors corresponds to those actually present in...

Страница 29: ...ending machine returns to the programming menu No other modes can be selected If the value is 1 One there is just one refrigerator probe connected the following message will appear when the F key is p...

Страница 30: ...back below the set threshold in the residual time remaining To prevent false out of order indications after prolonged operator intervention the various counters can be initialised through this functi...

Страница 31: ...F key to select the value VVVVV of the price line to be varied Enter the new value pressing the numbers on the keyboard confirm the price by pressing the F key again Note if the entered value is not...

Страница 32: ...0 65535 independent of the position of the comma e g with 2 decimals the maximum credit is 655 35 If set to 0 this control is disabled Default 0 COIN RETURN PARAMETERS If there is an MDB coin return...

Страница 33: ...machine it will be possible to set the reading and or recognition of the quantity and or value of coins or tokens present in the coin box tubes The following coin and tube parameters can be set by sel...

Страница 34: ...alue of the banknote Secur H recognition security level high Secur L low Enabl ON banknote enabled Enabl OFF banknote disabled Press F to enable disable the banknote press C to change the recognition...

Страница 35: ...m is installed To set the parameters of the RFID payment system RFID PRICE BRACKET If an RFID payment system is installed in the vending machine it allows selecting the price bracket to be associated...

Страница 36: ...erature control section and the description of the ERR L09 error message for the description Settable values 0 45 C To deactivate this function set it to 40 C Default 45 C OVERTEMPERATURE TIME Visible...

Страница 37: ...nnection with a handheld device that has a code other than 0 set AUDIT PARAMETERS NOTE It is possible to display a minimum list of sales data on the automatic vending machine If an MDB system is insta...

Страница 38: ...y using the appropriate keys OUT OF ORDER MOTORS Select this item to see which motors have generated an Out of Order condition The out of orders are also listed in this menu The following message will...

Страница 39: ...tivated the following message will appear if a malfunction occurs Where xxxxxx is the detected error See the Installation and service manual Problems and relative solutions chapter Motor anomaly messa...

Страница 40: ...ad that anomalies and or differences between the current configuration and the one detected during the self learning procedure have not been detected XX indicates the number of the recognised motors I...

Страница 41: ...5 induce a good efficency of the motor X and Y values inferior to 5 induce a low efficency of the motor Motor works as well but it is necessary to make the following controls in order to avoid future...

Страница 42: ...one of the three parameters should be at the ERR level the FTCA infrared system will be out of order and an OFF L10 message will be displayed see OFF message table for details When the following messa...

Страница 43: ...nternal code software Read only General Param s Software versions Displays software versions General Param s Default P Reset Card reinitialisation Password required General Param s Protected param Pro...

Страница 44: ...30 Refrig Param s Refueling time Restocking time 0 1000 min 120 Refrig Param s Connected probes Number of connected refrigerator probes Read only EVA DTS parameters Reset passcode Reset Security and P...

Страница 45: ...EN 61000 3 3 1995 A1 2001 A2 2005 EN 50366 2003 A1 2006 e soddisfa i requisiti essenziali della Direttiva 98 37 CE Declares that the machine described on the identification plate is in conformity wit...

Страница 46: ...relative to the installation and connection of the device to the power supply systems are not included in the warranty either Damian S r l is not responsible for possible injuries and damage to person...

Отзывы: