Serie "LXS9"

 

 
 

 

Pagina A - 11 

 

Rev. M - 01 

» 

C

OMPULSORY SALE

 

(Visible and programmable only if „MDB coin return‟ payment system installed)

 

If Enabled, the MDB payment system does not give change before a sale, to prevent it from being used 
as a coin changer. Settable values: 

Disable

d‟

 

(OFF), „

Enabled‟

 (ON). 

 

   

[ Default: 

Disabled ]

 

 
 

 
 
 

» 

M

ANUAL EMPTYING OF THE COIN TUBES

 

(Visible and programmable only if „MDB coin return‟ payment system installed)

 

If  activated  it  enables  the  manual  emptying  of  the  coin  tubes  through  the  pushbuttons  on  the  MDB 
payment system. Settable values: 

Disabled‟

 

(OFF), „

Enabled‟

 (ON). 

The emptying of the coin tubes performed by the programming is carried out as described further on: 

   

 

[ Default: 

Disabled

 ] 

 

 

 

 

» 

MDB

 SALES MODES

  (Visible and programmable onl

y if „MDB coin return‟ payment system installed)

 

To select the sales mode with an MDB payment system. Settable values:  

0) Single NoChang

‟, Single sale without change; at the end of the sale the change is cancelled. 

1) Change

‟ , Single sale with change; at the end of the sale the change is returned automatically 

2) Multi Vend

‟, Multiple sale: the residual credit is returned only if requested: 

 

[ Default: „

1) Change

‟  ] 

 
 

 

C

OINS AND TUBES

If  there  is  an  MDB  change  return  coin  box  installed  in  the  vending  machine,  it  will  be  possible  to set the 
reading and/or recognition of the quantity and/or value of coins or tokens present in the coin box tubes.

 

The following coin and tube parameters can be set by selecting this function. 

» 

C

OINS MANAGED BY THE COIN RETURN SYSTEM

 

(Visible and programmable only if „MDB coin return‟ payment system installed)

 

To  read  the  value  of  the  coins  present  in  the  MDB  payment  system  tubes,  and  to  enable  or  disable 
acceptance of these coins; also to empty the coins present in the tubes: 
 

 
 

 
 

“nn” number of the coin,  
“vvvvv” value of the coin,  
“xxx” number of coins in the tube, if the tube is not enabled it displays “---“,  
“yyy” =ON coin enabled, =OFF coin disabled 
Press the 

F

 key to enable/disable the coin. 

Press the 

 key to manually empty from 1 to 9 coins from the indicated tube. 

Note 1

: The value of the coins recognised by the payment system depends on the system itself; refer to 

the relative documentation. 

Note 2

: With some MDB payment systems the parameter  indicating the quantity of coins present could 

be handled by the payment system itself. Refer to the documentation of the payment system in use. 

Programming 
MDB parameter 

 

 

Coin retn.Param. 

->->->

 

 

Obligatory sale 

Current value

 

 

Programming 
MDB parameter 

 

 

Coin retn.Param. 

->->->

 

 

Enab.Man.Dispens 

Current value

 

 

Programming 
MDB parameter 

 

 

Coin retn.Param. 

->->->

 

 

Sale Modalit.MDB 

Current value

 

 

Programming 
MDB parameter 

 

 

Coins and tubes 

->->->

 

 

Coin nn vvvvv 
In tubes xxx yyy 

 

Содержание LXS9 Series

Страница 1: ...X INSTALLATION AND SERVICE PROGRAMMING This manual is for skilled service personnel only DAMIAN S R L VIA RAGAZZI DEL 99 N 30 21053 CASTELLANZA VA ITALY Rev M 01 Vers Software 1 1a or follow...

Страница 2: ...Serie LXS9 Pagina A 25 Rev M 01...

Страница 3: ...ed use for LXS9 series LUCE X SNAC automatic spiral vending machines consists of automatically distributing solid products or products in solid package pre packaged foods snacks bottled drinks etc and...

Страница 4: ...stem version Absent Super Minimum internal operating temperature 2 C Food zone only Environment Storage temperature 0 45 C Working temperature 5 32 C Max relative humidity 65 Dimensions and Weights He...

Страница 5: ...hildren should be supervised to make sure that they do not play with the vending machine Before checking any electrical part move the main switch of the vending machine See Figure 2 to the OFF positio...

Страница 6: ...them rest correctly on the ground When the vending machine is not levelled properly it can be difficult to close the door With the wall anchoring bracket kit accessory it is possible to anchor the ve...

Страница 7: ...d service personnel Before all operations on the power cord make sure that the power supply plug is disconnected from its outlet Remove the rear grille of the cabinet by unscrewing its fixing screws r...

Страница 8: ...ation of the executive payment systems Connect the Molex 15 pin female power connector of the vending machine to the corresponding connector on the payment system Refer to the payment system documenta...

Страница 9: ...iding panel motor 18 Sliding panel motor pinion 5 Two magnets for locking the Push door 12 Door open switch 6 Two microswitches of the Push locking magnets 13 Two beginning end stroke microswitches 19...

Страница 10: ...time B is prolonged by a value equal to the one set in the Restocking time C parameter Each time it is turned back on if the internal temperature exceeds the Safety temperature A but the conditions f...

Страница 11: ...probe has been replaced the problem is repeated the fault might be due to the CLP1 power board located in the electrical box OFF L02 Temperature probe 2 error These messages indicate a problem with th...

Страница 12: ...Sliding door test as explained further on OFF L12a Door Push EMagnet Fault Magnets for locking the Push door short circuited One or both magnets 5 for locking the door are short circuited Check their...

Страница 13: ...fter maintenance Check that the panel motor 11 power supply connection has not been inverted OFF L13e TimeOut SD Mot Sliding panel error during opening At the end of an opening cycle the sliding panel...

Страница 14: ...gnostic tests some motor anomaly messages might appear on the display these messages are listed below with the relative explanation as well as some possible solutions to the problem Motor xx Disconnec...

Страница 15: ...LAYED During normal vending machine operation some malfunctions of some motors may occur These malfunctions generate errors that can be automatically reset by the vending machine R or that can be not...

Страница 16: ...motors function is not activated If the problem persists make sure that the CPU card works and replace it if necessary THE MACHINE DOES NOT REACH THE REQUIRED TEMPERATURE Before carrying out any oper...

Страница 17: ...and disconnect the power supply wiring of the refrigerator from the electrical box Grasp the handle e at the base of the refrigeration unit and remove it from the normal work position by pulling it if...

Страница 18: ...te B F2 5x20 T6 3 6 3 A delayed 250 V General 24 28V The vending machine does not work C F3 5x20 T6 3 6 3 A delayed 250 V General 230V The vending machine does not work D F4 5x20 T6 3 6 3 A delayed 25...

Страница 19: ...that it turns on again only after it has been closed completely SLIDING PANEL CHECK AND LUBRICATION Sliding panel 10 operation can be checked by performing a door closing and opening test see programm...

Страница 20: ...roswitches and that the magnets can move freely After having reassembled the magnet covering panel perform a door closing and opening test see programm diagnostics Product door test CHECK CLEANING OF...

Страница 21: ...nctions provided for by the regulations in force 1 In the European Union If the equipment is marked on the outside with this symbol it should not be disposed of with normal household waste Contact you...

Страница 22: ...Serie LXS9 Page 21 Rev M 01...

Страница 23: ...tachment A PROGRAMMING SHEET This attachment is an integral part of the manual and must remain with it DAMIAN S R L VIA RAGAZZI DEL 99 N 30 21053 CASTELLANZA VA ITALY Rev M 01 Vers Software 1 1a or fo...

Страница 24: ...ain from the first parameter When the message relative to the desired parameter appears press the F Enter key to confirm TO CHANGE THE PROGRAMMED VALUE OF THE SELECTED PARAMETER If appears on the seco...

Страница 25: ...ght Kit installed Energy Saving allows activating two separate energy saving functions Save Mode function Kicks in after a programmed vending machine inactivity time and reduces the electrical consump...

Страница 26: ...Vivilight Kit installed This parameter allows setting the luminous intensity in of the LED lamps that light up the display window when the Night Mode function is activated Settable values 0 100 Defaul...

Страница 27: ...il or if the 3 step function is not active the vending machine still keeps the credit stored in memory and allows a new selection to be made When this function is selected it will be possible to set t...

Страница 28: ...appears on the display after selecting the desired language press F to confirm B This message appears on the display Check that the number of connected motors corresponds to those actually present in...

Страница 29: ...ending machine returns to the programming menu No other modes can be selected If the value is 1 One there is just one refrigerator probe connected the following message will appear when the F key is p...

Страница 30: ...back below the set threshold in the residual time remaining To prevent false out of order indications after prolonged operator intervention the various counters can be initialised through this functi...

Страница 31: ...F key to select the value VVVVV of the price line to be varied Enter the new value pressing the numbers on the keyboard confirm the price by pressing the F key again Note if the entered value is not...

Страница 32: ...0 65535 independent of the position of the comma e g with 2 decimals the maximum credit is 655 35 If set to 0 this control is disabled Default 0 COIN RETURN PARAMETERS If there is an MDB coin return...

Страница 33: ...machine it will be possible to set the reading and or recognition of the quantity and or value of coins or tokens present in the coin box tubes The following coin and tube parameters can be set by sel...

Страница 34: ...alue of the banknote Secur H recognition security level high Secur L low Enabl ON banknote enabled Enabl OFF banknote disabled Press F to enable disable the banknote press C to change the recognition...

Страница 35: ...m is installed To set the parameters of the RFID payment system RFID PRICE BRACKET If an RFID payment system is installed in the vending machine it allows selecting the price bracket to be associated...

Страница 36: ...erature control section and the description of the ERR L09 error message for the description Settable values 0 45 C To deactivate this function set it to 40 C Default 45 C OVERTEMPERATURE TIME Visible...

Страница 37: ...nnection with a handheld device that has a code other than 0 set AUDIT PARAMETERS NOTE It is possible to display a minimum list of sales data on the automatic vending machine If an MDB system is insta...

Страница 38: ...y using the appropriate keys OUT OF ORDER MOTORS Select this item to see which motors have generated an Out of Order condition The out of orders are also listed in this menu The following message will...

Страница 39: ...tivated the following message will appear if a malfunction occurs Where xxxxxx is the detected error See the Installation and service manual Problems and relative solutions chapter Motor anomaly messa...

Страница 40: ...ad that anomalies and or differences between the current configuration and the one detected during the self learning procedure have not been detected XX indicates the number of the recognised motors I...

Страница 41: ...5 induce a good efficency of the motor X and Y values inferior to 5 induce a low efficency of the motor Motor works as well but it is necessary to make the following controls in order to avoid future...

Страница 42: ...one of the three parameters should be at the ERR level the FTCA infrared system will be out of order and an OFF L10 message will be displayed see OFF message table for details When the following messa...

Страница 43: ...nternal code software Read only General Param s Software versions Displays software versions General Param s Default P Reset Card reinitialisation Password required General Param s Protected param Pro...

Страница 44: ...30 Refrig Param s Refueling time Restocking time 0 1000 min 120 Refrig Param s Connected probes Number of connected refrigerator probes Read only EVA DTS parameters Reset passcode Reset Security and P...

Страница 45: ...EN 61000 3 3 1995 A1 2001 A2 2005 EN 50366 2003 A1 2006 e soddisfa i requisiti essenziali della Direttiva 98 37 CE Declares that the machine described on the identification plate is in conformity wit...

Страница 46: ...relative to the installation and connection of the device to the power supply systems are not included in the warranty either Damian S r l is not responsible for possible injuries and damage to person...