![Dalsa Xtium-CLHS PX8 Скачать руководство пользователя страница 45](http://html.mh-extra.com/html/dalsa/xtium-clhs-px8/xtium-clhs-px8_user-manual_504474045.webp)
Xtium-CLHS PX8 User's Manual
Xtium-CLHS PX8 Reference
•
43
Shaft Encoder Direction = X, where:
•
X = 0, Ignore direction
•
X = 1, Forward steps are detected by pulse order A/B (forward motion)
•
X = 2, Forward steps are detected by pulse order B/A (reverse motion)
Note: For information on camera configuration files, see the Sapera Acquisition Parameters
Reference Manual (OC-SAPM-APR00).
Virtual Frame Trigger for Line Scan Cameras
When using line scan cameras, a frame buffer is allocated in host system memory to store
captured video lines. To control when a video line is stored as the first line in this “virtual” frame
buffer, an external frame trigger signal is used. The Sapera vertical cropping parameter controls
the number of lines sequentially grabbed and stored in the virtual frame buffer.
Virtual Frame Trigger Timing Diagram
The following timing diagram shows an example of grabbing 10 video lines from a line scan camera
and the use of a virtual frame trigger to define when a video line is stored at the beginning of the
virtual frame buffer. The virtual frame trigger signal (generated by some external event) connects
to the Xtium-CLHS PX8 trigger input.
Virtual frame trigger can be RS-422, TTL, 12V, or 24V industry standard, and be rising or falling
edge active, active high or low, or double pulse rising or falling edge.
In this example, virtual frame trigger control is configured for rising edge trigger.
Virtual frame trigger connects to the Xtium-CLHS PX8 via the External Trigger Input 1 & 2
inputs.
•
Trigger Input #1 on connector J1: pin 8
•
Trigger Input #2 on connector J1: pin 9
Camera control signals are active at all times. These continually trigger the camera acquisition
in order to avoid corrupted video lines at the beginning of a virtual frame.
The camera control signals are either timing controls on Xtium-CLHS PX8 shaft encoder inputs,
or line triggers generated internally by the Xtium-CLHS PX8.
The Sapera vertical cropping parameter specifies the number of lines captured.
Synchronization Signals for a 10 Line Virtual Frame
The following timing diagram shows the relationship between External Frame Trigger input,
External Shaft Encoder input (one phase used with the second terminated), and camera control
output to the camera.