72
•
Technical Specifications
Xtium-CLHS PX8 User's Manual
Block Diagram: Connecting External Receivers to the General Outputs
J1: External Signals Connector
(DH60-27P)
To External Devices
Xtium-CLHS PX8
1
Vcc
Compatible
Receiver
User Signal Ground
Reserved
26
27
:
:
25 :
24 :
23 :
General Output 4
22 :
General Output 3
21 :
19
20
:
:
18 :
17 :
General Input 4 (+)
16 :
General Input 3 (+)
15 :
Power Output (12 Volts)
14 :
Ground
13 :
General Output 2
12 :
General Output 1 / Strobe
11 :
Ground
10 :
General Input 2 / Trigger 2 (+)
9
:
General Input 1 / Trigger 1 (+)
8
:
7
:
Shaft Encoder B (+)
6
:
Shaft Encoder B (-)
5
:
Ground
4
:
Shaft Encoder A (+)
3
:
Shaft Encoder A (-)
2
:
Ground
1
:
General Input 1 / Trigger 1 (-)
General Input 4 (-)
General Input 3 (-)
Power Output (5 Volts)
General Input 2 / Trigger 2 (-)
General Output 5
General Output 6
General Output 7
General Output 8
2
Vcc
Compatible
Receiver
3
Vcc
Compatible
Receiver
4
Vcc
Compatible
Receiver
5
Vcc
Compatible
Receiver
6
Vcc
Compatible
Receiver
7
Vcc
Compatible
Receiver
8
Vcc
Compatible
Receiver
Figure 27:Output Signals Connection Diagram
External Receiver Electrical Requirements
Xtium General Outputs are standard TTL logic levels.
External receiver circuits must be compatible to TTL signals.
Xtium PX8
Output Level
Description
MIN
MAX
TTL
Output Voltage High
(V
H
)
2.0 V
–
Output Voltage Low
(V
L
)
–
0.8 V