encoder is used, Line0 -- Phase A , Line2 -- Phase B
Line Format
This feature returns or sets (if possible) the current
electrical format of the selected physical input Line: No
connect, TTL, LVDS
Line Connector Pin
Enumeration of the physical line (or pin) on the device
connector. This feature is not available when Line Format
is set to Not Connected and when Line Selector in set to a
line smaller than Line2
Line Function
Displays the line function
Line Debounce Factor
This feature control the minimum period of a input line
transition before detecting a signal transition.
Outputs Group
Parameter
Description
Output Selector
This feature selects which physical line (or pin) of the
external device connector to configure. When a Line is
selected, all the other Line features will be applied to its
associated I / O control block and will condition the
resulting input or output signal.
Line0 outputs signals at PLC_Q0; Line1 outputs signals at
PLC_Q1; Line2 outputs signals at PLC_Q2; Line3 outputs
signals at PLC_Q3.
Output Format
This feature returns or sets (if possible) the current
electrical format of the selected physical output Line: No
Connect, TTL, or LVDS
Gain, Black Level, and Background
The cameras provide gain and black level adjustments in the digital domain for the sensor.
The gain and black level controls can make small compensations to the acquisition in
situations where lighting varies and the lens iris cannot be easily adjusted. The user can
evaluate gain and black level using CamExpert.
The parameters that control gain, black level, and background are grouped together in the
Analog Controls set.
Note that calibrating the gain can take up to 10 seconds. Adjust the GUI’s timeout values
(in the Advanced Processing set) accordingly.
A section describing camera calibration in detail is available later in this manual.
GigE Vision Input Controls
Analog Controls
Parameter
Description
Light Source
Specifies the adjustment to the color gain values for a
given light source.