7.8 Saving and Restoring Settings
For each camera operating mode (high sensitivity forward direction, high sensitivity
reverse direction, low sensitivity, or tall pixel), the camera has distinct factory settings,
current settings, and user settings. In addition, there is one set of factory pre-calibrated
pixel coefficients and up to four sets of user created pixel coefficients for each operating
mode.
Figure 28: Saving and Restoring Overview
4 sets of user
pixel coefficients
User
Settings
Current
Session
wus wpc,wfc
,
rus lpc
,
Factory
Settings
1 set of factory
pixel coefficients
For each camera operating mode:
Low Sensitivity
High Sensitivity Forward
High Sensitivity Reverse
Tall Pixel
Factory Settings
On first initialization, the camera operates using the factory settings. You can restore the
original factory settings at any time using the command
rfs
.
User Settings
You can save or restore your user settings to non-volatile memory using the following
commands. Pixel coefficients and LUTs are stored separately from other data.
•
To save all current user settings to non-volatile memory, use the command
wus
. The
camera will automatically restore the saved user settings when powered up.
Note:
While settings are being written to nonvolatile memory, do not power down camera
or camera memory may be corrupted.
•
To restore the last saved user settings, use the command
rus
.
•
To save the current pixel coefficients, use the command
wpc
and
wfc
.
•
To restore the last saved pixel coefficients, use the command
lpc
.
•
To write and load LUTs, use the
wil
and
lil
commands, respectively.
Current Session Settings
These are the current operating settings of your camera. To save these settings to non-
volatile memory, use the command
wus
.
Содержание Spyder 3 S3-10-01k40-00-R
Страница 22: ...22 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 30: ...30 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 42: ...42 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 57: ...Spyder 3 CL User s Manual PRELIMINARY 57 DALSA 03 032 20008 03 Example sag 0 5 2 Related Commands ccg ...
Страница 104: ...104 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 112: ...112 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 114: ...114 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...