![Dalsa Spyder 3 S3-10-01k40-00-R Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/dalsa/spyder-3-s3-10-01k40-00-r/spyder-3-s3-10-01k40-00-r_user-manual_504411034.webp)
34
PRELIMINARY
Spyder 3 CL User's Manual
03-032-20008-03
DALSA
m
f
OD
=
′
These equations can be combined to give their most useful form:
′
=
′
h
h
f
OD
This is the governing equation for many object and
image plane parameters.
Example: An acquisition system has a 512 x 512 element, 10 m pixel pitch area scan
camera, a lens with an effective focal length of 45mm, and requires that 100
μ
m in the
object space correspond to each pixel in the image sensor. Using the preceding equation,
the object distance must be 450mm (0.450m).
10
100
45
450
0 450
μ
μ
m
m
mm
OD
OD
mm
m
=
=
( .
)
4.3 Electrical Interface
The Spyder 3 CL cameras have been designed for EMC compliance. The test setup has
been verified to the following EMC standards:
•
CISPR-11:2004
•
EN 55011:2003
•
EN 61326:2002
To achieve EMC compliance, follow these specific guidelines:
•
Ensure that all cable shields have 360
°
electrical connection to the connector.
•
Fasten and secure all connectors.
Содержание Spyder 3 S3-10-01k40-00-R
Страница 22: ...22 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 30: ...30 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 42: ...42 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 57: ...Spyder 3 CL User s Manual PRELIMINARY 57 DALSA 03 032 20008 03 Example sag 0 5 2 Related Commands ccg ...
Страница 104: ...104 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 112: ...112 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 114: ...114 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...