![Dalsa Spyder 3 S3-10-01k40-00-R Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/dalsa/spyder-3-s3-10-01k40-00-r/spyder-3-s3-10-01k40-00-r_user-manual_504411062.webp)
62
PRELIMINARY
Spyder 3 CL User's Manual
03-032-20008-03
DALSA
Digital Signal Processing
To optimize camera performance, digital signal processing should be completed after any
analog adjustments.
FPN Correction
Performing FPN Correction
Syntax:
Performs FPN correction and eliminates FPN noise by removing
individual pixel dark current.
Syntax:
ccf
Notes:
•
Perform all analog and digital adjustments before
performing FPN correction.
•
Perform FPN correction before PRNU correction.
•
Refer to Calibrating the Camera to Remove Non-Uniformity
(Flat Field Correction) on page 59 for a procedural overview
on performing flat field correction.
•
To save FPN coefficients after calibration, use the
wfc
command. Refer to section 7.9 Saving and Restoring PRNU
and FPN Coefficients for details.
Related Commands:
ccp
,
wfc
Example:
ccf
Setting a Pixel’s FPN Coefficient
Purpose:
Sets an individual pixel’s FPN coefficient.
Syntax
sfc x i
Syntax Elements:
x
The pixel number from
1
to
sensor pixel count
.
i
Coefficient value in a range from
0
to
2047
(12 bit LSB).
Example:
sfc 10 50
Содержание Spyder 3 S3-10-01k40-00-R
Страница 22: ...22 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 30: ...30 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 42: ...42 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 57: ...Spyder 3 CL User s Manual PRELIMINARY 57 DALSA 03 032 20008 03 Example sag 0 5 2 Related Commands ccg ...
Страница 104: ...104 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 112: ...112 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...
Страница 114: ...114 PRELIMINARY Spyder 3 CL User s Manual 03 032 20008 03 DALSA ...