Spyder 3 GigE User’s Manual
DALSA 03-032-10158-09
9
Operating Specifications (12 bit values, Flat Field Correction enabled)
-10dB
0dB
+10dB
Specification
Unit
Min
Typ
Max
Min
Typ
Max
Min
Typ
Max
Notes
PRNU ECD
Uncorrected Local
Uncorrected Global
Corrected Local
Corrected Global
%
%
DN p-p
DN p-p
8.5%
10%
80
80
8.5%
10%
80
80
8.5%
10%
95
95
1
PRNU ECE
Uncorrected Local
Uncorrected Global
Corrected Local
Corrected Global
%
%
DN p-p
DN p-p
8.5%
10%
80
80
12%
12%
208
208
37%
37%
752
752
SEE (calculated)
Dual line
Single line
nJ/cm
2
6.35
12.2
1.92
4.0
0.61
1.2
NEE (calculated)
Dual line
Single line
pJ/cm
2
4.6
9.2
4.5
9.3
4.6
9.2
Sat. Output
Amplitude
DN
3968±80
DC
Offset
DN
96
160
336
Test conditions unless otherwise noted:
•
CCD Pixel Rate: 40 MHz per sensor tap.
•
Line Rate: 5000 Hz.
•
Nominal Gain setting unless otherwise specified.
•
Light Source: Broadband Quartz Halogen, 3250k, with 750 nm highpass filter
installed.
•
Ambient test temperature 25 °C.
•
Unless otherwise specified, all values are referenced at 12 bit.
•
Exposure mode disabled.
•
Unless specified, dual line mode.
Notes
1. PRNU measured at 50% SAT.
Содержание Spyder 3 GigE SG-10-01k80-00-R
Страница 17: ...Spyder 3 GigE User s Manual DALSA 03 032 10158 09 17 ...
Страница 37: ...Spyder 3 GigE User s Manual DALSA 03 032 10158 09 37 ...
Страница 43: ...Spyder 3 GigE User s Manual DALSA 03 032 10158 09 43 ...
Страница 47: ...Spyder 3 GigE User s Manual DALSA 03 032 10158 09 47 ...
Страница 115: ...Spyder 3 GigE User s Manual DALSA 03 032 10158 09 115 ...