Spyder 3 GigE User’s Manual
DALSA 03-032-10158-09
29
2.5 Camera LED
The camera is equipped with a red/green LED used to display the operational status of
the camera. The table below summarizes the operating states of the camera and the
corresponding LED states.
When more than one condition is active, the LED indicates the condition with the highest
priority. Error and warning states are accompanied by corresponding messages further
describing the current camera status.
Table 6: Diagnostic LED
Priority
Color of Status LED
Meaning
1
Flashing Red
Fatal Error. For example, camera temperature is too
high and camera thermal shutdown has occurred.
2
Flashing Green
Camera initialization or executing a long command
(e.g., flat field correction commands
ccp
or
ccf
)
3
Solid Green
Camera is operational and functioning correctly
2.6 Camera Timing
Table 7: Camera Link Timing Parameter Table
Units Min.
Typ.
Max.
Notes
tLine_Period
μ
s
27.78
1000
1K 1 Tap
14.71
1000
1K 2 Tap
54.1
1000
2K 1 Tap
27.78
1000
2K 2 Tap
twSync ns
100
twSYNC_INT
ns
100
(3000*)
For exposure mode
4 this value needs to
be >3000ns other
wise >100ns
Содержание Spyder 3 GigE SG-10-01k80-00-R
Страница 17: ...Spyder 3 GigE User s Manual DALSA 03 032 10158 09 17 ...
Страница 37: ...Spyder 3 GigE User s Manual DALSA 03 032 10158 09 37 ...
Страница 43: ...Spyder 3 GigE User s Manual DALSA 03 032 10158 09 43 ...
Страница 47: ...Spyder 3 GigE User s Manual DALSA 03 032 10158 09 47 ...
Страница 115: ...Spyder 3 GigE User s Manual DALSA 03 032 10158 09 115 ...