Appendix A
Spyder 3 GigE ASCII Commands
Serial Protocol Defaults
•
8 data bits
•
1 stop bit
•
No parity
•
No flow control
•
9.6kbps
•
Camera does not echo characters
Command Format
When entering commands, remember that:
•
A carriage return <CR> ends each command.
•
The camera will answer each command with either <CR><LF> “OK >" or
<CR><LF>"Error xx: Error Message >" or “Warning xx: Warning Message”. The ">"
is always the last character sent by the camera.
The following parameter conventions are used in the manual:
•
i
= integer value
•
f
= real number
•
m
= member of a set
•
s
= string
•
t
= tap id
•
x
= pixel column number
•
y
= pixel row number
Example: to return the current camera settings
gcp
<CR>