32
•
Part I: PC2-CamLink Board
PC2-CamLink User's Manual
Sapera Parameters for Area Scan Trigger:
CORACQ_PRM_EXT_TRIGGER_ENABLE = {
CORACQ_VAL_EXT_TRIGGER_OFF, CORACQ_VAL_EXT_TRIGGER_ON}
CORACQ_PRM_EXT_TRIGGER_DETECTION = {
CORACQ_VAL_RISING_EDGE, CORACQ_VAL_FALLING_EDGE,
CORACQ_VAL_ACTIVE_LOW, CORACQ_VAL_ACTIVE_HIGH}
CORACQ_PRM_EXT_TRIGGER_DURATION: Debounce duration
CORACQ_PRM_EXT_TRIGGER_FRAME_COUNT: Number of frames to acquire per
trigger
CORACQ_PRM_EXT_TRIGGER_LEVEL = { CORACQ_VAL_LEVEL_TTL,
CORACQ_VAL_LEVEL_LVDS}
CORACQ_PRM_EXT_TRIGGER_SOURCE = {0 for automatic (defaults to trigger
input 1) }
CORACQ_PRM_INT_FRAME_TRIGGER_ENABLE = {TRUE, FALSE}
CORACQ_PRM_INT_FRAME_TRIGGER_FREQ: Frequency of user timer
In CamExpert, the external trigger parameters are located under the ‘External Trigger
Parameters’ tab. The internal frame trigger parameters are located under the ‘Advanced
Control Parameters’ tab.
IFC
IFC Parameters for Area scan Trigger:
P_TRIGGER_ENABLE = {IFC_DISABLE, IFC_ENABLE}
P_TRIGGER_POLARITY = {IFC_FALLING_EDGE, IFC_RISING_EDGE,
IFC_POL_ACTIVE_HIGH, IFC_POL_ACTIVE_LOW}
P_GEN_SW_TRIGGER = {0, 1}
P_TRIGGER_DEBOUNCE: Debounce duration
P_FRAMES_PER_TRIGGER: Number of frames to acquire per trigger
CL2_FRAME_TRIG_SRC = {CL2_SOFT_FRAME_TRIG,
CL2_OPTO_FRAME_TRIG1, CL2_OPTO_FRAME_TRIG2,
CL2_LVDS_FRAME_TRIG1, CL2_LVDS_FRAME_TRIG2,
CL2_FREQ_FRAME_TRIG }
CL2_FRAME_TRIG_FREQ: Frequency of user timer trigger source
Linescan Triggers
External triggers allows line acquisition to be synchronized to external events. When acquiring a line
in External Trigger mode, the acquisition will not start until the PC2-CamLink receives a trigger
signal. Acquisition begins with the next valid line after the trigger.
Two trigger events, the shaft encoder or a user timer, can fire the EXSYNC and PRIN pulse generators
for linescan cameras.
Linescan acquisition relies on the concept of virtual frames to simplify transfer to the host. Basically, a
virtual frame is defined as a number of consecutive lines that are grouped together into a single host
buffer.
Содержание PC2-CamLink
Страница 7: ...PC2 CamLink User s Manual Part I PC2 CamLink Board 3 Part I PC2 CamLink Board ...
Страница 8: ...4 Part I PC2 CamLink Board PC2 CamLink User s Manual ...
Страница 10: ...6 Part I PC2 CamLink Board PC2 CamLink User s Manual EC FCC Certificate of Conformity ...
Страница 83: ...PC2 CamLink User s Manual Part I PC2 CamLink Board 79 ...
Страница 84: ......
Страница 85: ...PC2 CamLink User s Manual Part II Sapera LT 81 Part II Sapera LT ...
Страница 86: ...82 Part II Sapera LT PC2 CamLink User s Manual ...
Страница 105: ...PC2 CamLink User s Manual Part III IFC 101 Part III IFC ...
Страница 106: ...102 Part III IFC PC2 CamLink User s Manual ...
Страница 116: ...112 Part III IFC PC2 CamLink User s Manual ...
Страница 117: ...PC2 CamLink User s Manual Part IV Troubleshooting and Support 113 Part IV Troubleshooting and Support ...
Страница 118: ...114 Part IV Troubleshooting and Support PC2 CamLink User s Manual ...
Страница 130: ...126 Glossary of Terms PC2 CamLink User s Manual ...