The EXSYNC signal can be selected as an output on any of the four camera control lines on the
Camera Link™ connector.
Note:
The EXSYNC pulse is always fired from the selected trigger event.
EXSYNC can be used as the exposure input to some area scan cameras. EXSYNC might also be used
as the line transfer input on some linescan cameras.
Sapera Parameters for EXSYNC:
Refer to Time Integration method in the
Sapera Acquisition Parameters Reference
manual. EXSYNC is typically designated by pulse #1 in the various time integration
methods.
CORACQ_PRM_TIME_INTEGRATE_METHOD: Method to use for time integration
CORACQ_PRM_TIME_INTEGRATE_PULSE1_DELAY: Pulse offset from trigger
event
CORACQ_PRM_TIME_INTEGRATE_PULSE1_DURATION: Size of pulse
CORACQ_PRM_TIME_INTEGRATE_PULSE1_POLARITY =
{CORACQ_VAL_ACTIVE_LOW, CORACQ_VAL_ACTIVE_HIGH}
Note: Sapera also supports Camera Reset and Camera Trigger methods. Refer to the
Sapera Acquisition Parameters Reference
manual for more information.
In CamExpert, these parameters are found under the ‘Advanced Control Parameters’
tab. Select one of the camera control methods (camera reset, camera trigger, or time
integration).
IFC
IFC Parameters for EXSYNC:
CL2_EXSYNC_ENABLE = {IFC_DISABLE, IFC_ENABLE}
CL2_EXSYNC_POLARITY = {IFC_ACTIVE_LOW, IFC_ACTIVE_HIGH}
CL2_EXT_SYNC_OFFSET_TIME: Pulse offset from trigger event
CL2_EXT_SYNC_ACTIVE_TIME: Size of pulse
CL2_ COMBINE_EXSYNC_PRI = {IFC_DISABLE, IFC_ENABLE}
PRIN
The PRIN output signal is used by some cameras to control the integration time. PRIN is a
programmable pulse generator: the delay from the trigger and the pulse duration are programmable
from 1µs to 65seconds. The polarity of the PRIN output is programmable.
Содержание PC2-CamLink
Страница 7: ...PC2 CamLink User s Manual Part I PC2 CamLink Board 3 Part I PC2 CamLink Board ...
Страница 8: ...4 Part I PC2 CamLink Board PC2 CamLink User s Manual ...
Страница 10: ...6 Part I PC2 CamLink Board PC2 CamLink User s Manual EC FCC Certificate of Conformity ...
Страница 83: ...PC2 CamLink User s Manual Part I PC2 CamLink Board 79 ...
Страница 84: ......
Страница 85: ...PC2 CamLink User s Manual Part II Sapera LT 81 Part II Sapera LT ...
Страница 86: ...82 Part II Sapera LT PC2 CamLink User s Manual ...
Страница 105: ...PC2 CamLink User s Manual Part III IFC 101 Part III IFC ...
Страница 106: ...102 Part III IFC PC2 CamLink User s Manual ...
Страница 116: ...112 Part III IFC PC2 CamLink User s Manual ...
Страница 117: ...PC2 CamLink User s Manual Part IV Troubleshooting and Support 113 Part IV Troubleshooting and Support ...
Страница 118: ...114 Part IV Troubleshooting and Support PC2 CamLink User s Manual ...
Страница 130: ...126 Glossary of Terms PC2 CamLink User s Manual ...