74
•
Operational Reference
Linea2 5GigE Series Camera
Example: CounterStartSource = Line (Edge Base) Example 2
Countermode = OFF
Counter is
IDLE
CounterEnd Event Generated
CounterStartSource =
Line 1
Counter
Trigger Wait
Counter Register
Countermode = Active
Counter
Completed
CounterResetSource =
CounterEnd(Itself)
CounterStartSource = Line (Edge Base ) Example 2
Active
Active
Active
CounterTriggerActivation =
Falling Edge
Counter STATUS
0
12
8
5
10
Any Tick in
CounterEventSource
Active
1
1
CounterDuration = 12
0
The Second StartSource Pulse is ignored
Figure 53: Example
–
CounterStartSource = Line (Edge Base)