46
•
Operational Reference
Linea SWIR GigE Series Camera
Rising Edge
RisingEdge Starts counting on rising edge of the selected Line.
Falling Edge
FallingEdge Starts counting on falling edge of the selected Line.
Any Edge
AnyEdge Starts counting on the falling or rising edge of the
selected Line.
CounterIncremental
Source
counterIncrementalSource
Select the event source which increments the
counter. The
Event Control section
provides
details and timing diagrams for the supported
events.
1.00
Expert
DFNC
Off
Off Counter is stopped.
Acquisition Start
AcquisitionStart Counts the number of Acquisition Start events.
Exposure Start
ExposureStart Counts the number of Exposure Start events.
Exposure End
ExposureEnd Counts the number of Exposure End events.
Frame Start
FrameStart Counts the number of Frame Start events.
Line 1
Line1 Counts the number of transitions on Line 1 (based
on the counterIncrementalLineActivation feature
setting)
Line 2
Line2 Counts the number of transitions on Line 2 (based
on the counterIncrementalLineActivation feature
setting)
Rotary Encoder
rotaryEncoder1 The counter increments on rotary encoder ticks.
Internal Clock
InternalClock The counter increments on each microsecond tick
of the device internal Clock.
Timer 1 End
Timer1End Counts the number of Timer 1 End events.
Rejected Trigger
InvalidTrigger Counts the number of invalid triggers.
Counter Incremental Line
Activation
counterIncrementalLineActivation
Selects the counter signal activation mode for line
inputs. The counter increments on the specified
signal edge or level.
1.00
Expert
DFNC
Rising Edge
RisingEdge Increment the counter on the rising edge of the
selected I/O Line.
Falling Edge
FallingEdge Increment the counter on the falling edge of the
selected I/O Line.
Any Edge
AnyEdge Increment the counter on the falling or rising edge
of the selected I/O Line.
Counter Reset Source
counterResetSource
Selects the signal source to reset the counter then
waits for the next countStartSource signal or
event.
1.00
Expert
DFNC
Reset Cmd
Off Reset on reception of the Reset Icommand.
Acquisition Start
AcquisitionStart Reset on reception of the Acquisition Start.
Acquisition End
AcquisitionEnd Reset on reception of the Acquisition End.
Exposure Start
ExposureStart Reset on reception of the Exposure Start event.
Exposure End
ExposureEnd Reset on reception of the Exposure End event.
Line 1
Line1 Reset counter on the specified transition on line 1.
Line 2
Line2 Reset counter on the specified transition on line 2.
Timer 1 End
Timer1End Reset on reception of the Timer 1 End.
Counter 1 End
Counter1End Reset on the reception of the Counter 1 End.
Counter Reset Input Line
Activation
counterResetLineActivation
Specify the edge transition on the selected line that
will reset the selected counter.
1.00
Expert
DFNC
Rising Edge
RisingEdge Reset counter on rising edge of the selected signal.
Falling Edge
FallingEdge Reset counter on falling edge of the selected
signal.
Any Edge
AnyEdge Reset counter on the falling or rising edge of the
selected signal.