File Access Control Category
The File Access control in CamExpert allows the user to quickly upload various data files to
the connected camera. The supported data files are for camera firmware updates, Flat Field
coefficients, LUT data tables, and a custom image for use as an internal test pattern.
Features listed in the description table but tagged as
Invisible
are usually for Teledyne
DALSA or third party software usage—not typically needed by end user applications.
File Access Control Feature Descriptions
Display Name
Feature
Description
View
File Selector
FileSelector
Selects the file to access. The file types which are
accessible are device-dependent.
1.00
Beginner
FPGA Code
Firmware1
Upload new FPGA to the camera which will execute
on the next camera reboot cycle.
DFNC
Micro Code
Upload new micro codeto the camera which will
execute on the next camera reboot cycle.
CCI
Upload new CCI to the camera which will execute
on the next camera reboot cycle.
XML
Upload new XML to the camera which will execute
on the next camera reboot cycle.
User Set
Use UserSetSelector to specify which user set to
access.
Factory FlatField
coefficients
Use UserSetSelector to specify which user flatfield
to access.