54
Operational Reference
Genie Monochrome Series-GigE Vision Camera
Input Controls via Sapera LT or GigE Vision Compliant Applications
Sapera
Genie Sapera parameters for Trigger Modes, Time Stamp and General Inputs:
TriggerDelayToIntegration
= Delay in µs from trigger to exposure
TriggerEnable
= {FALSE, TRUE}
TriggerSource
= {Input 1 = 0, Input 2 = 1, Software = 2}
TriggerSoftware
= {FALSE, TRUE}
FramesPerTrigger
= Frame count 1 to 64k
TimestampResetSource
= {Off = 0, Input 1 = 1, Input 2 = 2}
TimestampCounter
= {Internal Clock = 0, Input 1 = 1, Input 2 = 2, End of Readout = 3}
TimestampReset
= {FALSE, TRUE}
PolarityInput_x
= {Active High = 0, Active Low = 1}
DebounceInput_x
= debouncing period in µs (from 1 to 255 µs)
InputPinStatusInput_1
= {Low, High}
InputPinStatusInput_2
= {Low, High}
See
"
Accessing Features with + LT
" on page 74
.
XML features for Trigger Modes, Time Stamp and General Inputs:
TriggerMode
= {Off = 0, On = 1}
TriggerSelector
= Select the type of trigger to control. FrameStart currently supported.
TriggerSoftware
= Generates a software trigger to start the acquisition in any trigger mode
TriggerSource
= External input or software signal as trigger source {Line2 = 1, Software = 2}
TriggerActivation
= {LevelLow = 0, LevelHigh = 1, RisingEdge, FallingEdge, AnyEdge}
TriggerDelayAbs
= Absolute delay to apply in us after reception of the trigger signal before
starting exposure
TriggerDelayRaw
= Absolute delay to apply in us after reception of the trigger signal before
starting exposure
GevTimestampTickFrequency
= 64-bit value indicating the number of timestamp clock ticks in
one second.
GevTimestampControlLatch
= Latches the current timestamp value of the device.
GevTimestampControlReset
= Resets the timestamp count of the device.
GevTimestampValue
= Latched 64-bit value of the timestamp. Value must first be latched using
GevTimestampControlLatch.
CounterSelector
= Select counter to configure. Currently only Timestamp is supported.
CounterEventSource
= Select counter source as {Internal Clock = 0, Input 1 = 1, Input 2 = 2,
End of Readout = 3}
CounterLineSource
= Source for the line to count.
CounterReset
= Resets the selected Counter.
InputLineSelector
= Index to general input {input1=0, input2=1}
InputLinePolarity
= {Active High = 0, Active Low = 1}
InputLineDebouncingPeriod
= debounce period in µs (from 1 to 255 µs)
InputLineValue
= Read input line state {low=0, high=1}
LineStatus
= Current logical state of signal at time of polling {FALSE, TRUE}
Line Mode
= Indicate if the line is an input or an output.