Genie Color Series-GigE Vision Camera
Operational Reference
49
Reset Mode
Exposure starts immediately after a valid trigger. There is no jitter on the start of exposure.
Exposure time is programmable or controlled by the trigger pulse width.
Minimum exposure is the sensor minimum (see Genie Sensor Overview), maximum is 16 seconds, with control
steps of 1µs.
Sensor readout must complete before the next exposure can start. That is, exposure and readout are sequential.
Therefore, the maximum frame rate is lower than for Synchronous mode.
Any external trigger received before the previous exposure/read out sequence is complete is ignored. An
application can elect to receive messages about ignored triggers. See
"
Events
" on page 69
.
Reset Mode Timing example for Genie C640
Synchronization Mode via Sapera LT or GigE Vision Compliant
Applications
Sapera
Genie Sapera parameters for Synchronization Mode:
ExposureAlignment
= {Synchronous = 0, Reset = 1}
In CamExpert, these parameters are available under the “Sensor” tab in the “Exposure Control”
dialog box.
See
"
Accessing Features with + LT
" on page 73
.
XML features for Synchronization Mode:
ExposureAlignment
= {Synchronous = 0, Reset = 1}
Содержание Genie Color C640
Страница 90: ...88 Operational Reference Genie Color Series GigE Vision Camera...
Страница 94: ...92 Network Overview Tools Genie Color Series GigE Vision Camera...
Страница 101: ...Genie Color Series GigE Vision Camera Technical Specifications 99 Genie 3D View with Right angle C mount and CS mount...
Страница 118: ...116 Technical Specifications Genie Color Series GigE Vision Camera EC FCC Declaration of Conformity...
Страница 130: ...128 Glossary of Terms Genie Color Series GigE Vision Camera...