Falcon2 4M, 8M, and 12M Camera User's Manual
55
Teledyne DALSA
03-032-20107-03
N ame
flatfieldCorrectionOffset
Disp lay N am e
Pixel Offset(FPN )
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Beginner
Access
Read -Write w hen in Calibration Mod e
Typ e
Integer
Valu es
0 to 127
N otes
Sets the offset to ap p ly to the cu rrently selected p ixel.
N ame
flatfieldCalibrationClearCoefficient
Disp lay N am e
Clear Coefficients
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Exp ert
Access
Read -Write w hen in Calibration Mod e
Typ e
Com m and
N otes
This featu re is u sed to clear all the cu rrent FPN and PRN U coefficients in the selected Active
Set.
N ame
flatfieldCalibrationSampleSize
Disp lay N am e
Calibration Sample Size
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Beginner
Access
Read -Only
Typ e
Integer
Valu es
64
N otes
The nu m ber of im ages to average to p erform the calibration.
N ame
flatfieldCalibrationFPN
Disp lay N am e
Offset(FPN ) Calibration
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Exp ert
Access
Read -Write w hen in Calibration Mod e
Typ e
Com m and
N otes
Perform s fixed p attern noise (FPN ) calibration. FPN calibration elim inates fixed p attern noise
by su btracting all non -u niformities and d ark cu rrent to obtain near 0 DN ou tp u t in the d ark
(no light exp osed to the sensor).
N ame
flatfieldCalibrationTarget
Disp lay N am e
Gain Calibration Target
N am e Sp ace
DFN C
Firm w are Release
00
Visibility
Exp ert
Access
Read -Write w hen in Calibration Mod e
Typ e
Float
Units
%
Valu es
0 to 100
N otes
Sets the target p ixel valu e for the gain (PRN U) calibration. It is sp ecified as a p ercentage of the
ou tp u t range (for exam p le, 1023 DN for 10 bits).