Falcon2 4M, 8M, and 12M Camera User's Manual
51
Teledyne DALSA
03-032-20107-03
Figure 18 Opto-coupled input
Each inp u t incorp orates a signal d ebou nce circu it (follow ing the op to -cou p ler) to elim inate short noise
transitions that cou ld incorrectly be interp reted as a valid p u lse. The d u ration is u ser p rogram m able from
1 µs to 255 µs u sing Cam Exp ert.
Opto-Coupled Outputs
The ou tp u ts are u np ow ered d evices and requ ire external p ow er. The sim p lified d iagram below
d em onstrates the need for a p u ll-u p resistor w hen u sing the ou tp u ts.
Figure 19: Simplified General Purpose Output Diagram
Advanced Processing Control Category
The Falcon2 Advanced Processing controls, as shown by CamExpert, groups parameters used to configure
Defective Pixel Detection, Flat Field calibration. Parameters in gray are read only, either always or due to another
parameter being disabled. Parameters in black are user set in CamExpert or programmable via an imaging
application.
Note that the features listed in the description table but tagged as
Invisible
are usually for Teledyne DALSA Support
or third party software usage—and not typically required by end-user applications.