Nano Series GigE Vision Camera
Operational Reference
•
207
Acquisition and Transfer Control Feature Descriptions
The following table describes these parameters along with their view attribute and minimum
camera firmware version required. Additionally the Device Version column will indicate which
parameter is a member of the DALSA Features Naming Convention (denoted by DFNC), versus the
GenICam Standard Features Naming Convention (SFNC tag is not shown).
The Device Version number represents the camera software functional group, not a firmware
revision number. As Genie Nano capabilities evolve the device version tag will increase, therefore
identifying the supported function package. New features for a major device version release will be
indicated by
green text
for easy identification.
Display Name
Feature & Values
Description
Device Version
& View
Acquisition Status
Selector
AcquisitionStatusSelector
Selects the internal acquisition signal to read
using AcquisitionStatus.
1.00
Expert
Acquisition Active
AcquisitionActive Device is currently doing an acquisition of one or
many frames.
Acquisition Trigger
Wait
AcquisitionTriggerWait Device is currently waiting for a trigger to start
the acquisition.
(
Ver. 1.05
)
Acquisition Status
AcquisitionStatus
Reads the state of the internal acquisition signal
selected using the Acquisition Status Selector
feature. (i.e. False / True)
1.00
Expert
Acquisition Mode
AcquisitionMode
Set the acquisition mode of the device. It defines
the number of frames to capture during an
acquisition and the way the acquisition stops.
1.00
Beginner
Single Frame
SingleFrame One frame is captured for each AcquisitionStart
Command. An AcquisitionStop occurs at the end
of the Active Frame.
Multi-Frame
MultiFrame A sequence of frames is captured for each
AcquisitionStart Command. The number of frames
is specified by AcquisitionFrameCount feature. An
AcquisitionStop occurs at the end of the Active
Frame(s)
Continuous
Continuous Frames are captured continuously with
AcquisitionStart until stopped with the
AcquisitionStop command.
Acquisition Frame Count AcquisitionFrameCount
Number of frames to be acquired in MultiFrame
acquisition mode.
1.00
Beginner
Internal Acquisition FPS
internalAcquisitionFPS
Specifies the camera internal frame rate, in Hz.
Use the AcquisitionFrameRate feature to control
this value.
1.08
Guru
Internal Acquisition
Frame Drop Count
internalAcquisitionFrameDropCount
Number of acquired frames to drop internally
between each transmitted frame Note that
acquisition events will be generated for all
frames, even if they are subsequently dropped.
1.08
Guru
Resulting Frame Rate
resultingTransferFPS
Reports the transfer frame rate, based on the
current AcquisitionFrameRate and
internalAcquisitionFrameDropCount. This feature
does not take bandwidth limitations into account.
1.08
Guru
Acquisition Arm Cmd
AcquisitionArm
Arms the device before an AcquisitionStart
command. This optional command validates all
the current features for consistency and prepares
the device for a fast start of the acquisition. If not
used explicitly, this command is automatically
executed at the first AcquisitionStart but will not
be repeated for subsequent ones unless a data
transfer related feature is changed in the device.
1.00
Guru
Acquisition Start Cmd
AcquisitionStart
Start image capture using the currently selected
acquisition mode. The number of frames captured
is specified by AcquisitionMode feature.
1.00
Beginner
Содержание C1240
Страница 215: ...Nano Series GigE Vision Camera Operational Reference 205 ...
Страница 254: ...244 Technical Specifications Nano Series GigE Vision Camera Note Genie Nano with C or CS Mount ...
Страница 271: ...Nano Series GigE Vision Camera Technical Specifications 261 EC FCC Declarations of Conformity Models M C1920 M C1940 ...
Страница 272: ...262 Technical Specifications Nano Series GigE Vision Camera Models M C640 M C800 M C1280 M C1930 M C2590 ...
Страница 273: ...Nano Series GigE Vision Camera Technical Specifications 263 Models M C2020 M C2050 M C2420 M C2450 ...
Страница 274: ...264 Technical Specifications Nano Series GigE Vision Camera Models M C4020 M C4030 M C4040 M C4060 ...
Страница 275: ...Nano Series GigE Vision Camera Technical Specifications 265 Models M C4090 M C5100 ...
Страница 276: ...266 Technical Specifications Nano Series GigE Vision Camera Models M C700 M C1450 ...
Страница 277: ...Nano Series GigE Vision Camera Technical Specifications 267 Model M C1950 ...
Страница 278: ...268 Technical Specifications Nano Series GigE Vision Camera Model C4900 ...
Страница 295: ...Nano Series GigE Vision Camera Additional Reference Information 285 Cable Assembly G3 AIOC BLUNT1M ...
Страница 296: ...286 Additional Reference Information Nano Series GigE Vision Camera Cable Assembly G3 AIOC BLUNT2M ...
Страница 297: ...Nano Series GigE Vision Camera Additional Reference Information 287 ...
Страница 298: ...288 Additional Reference Information Nano Series GigE Vision Camera Cable Assembly G3 AIOC BRKOUT2M ...
Страница 299: ...Nano Series GigE Vision Camera Additional Reference Information 289 ...
Страница 300: ...290 Additional Reference Information Nano Series GigE Vision Camera Nano Generic Power Supply with no I O ...
Страница 302: ...292 Additional Reference Information Nano Series GigE Vision Camera Cable Assembly Right Angle I O to Euro Block ...