1M28 and 1M75 User’s Manual
PRELIMINARY
33
DALSA
03-32-00525-03
2.
Select Camera
→
Registers. The Registers dialog box opens:
3.
In the left text boxes, enter the register values you wish to view.
4.
Click Reread all.
The current register values are displayed in the right text boxes.
5.
In the right text box, change the current value to the new value and click Change.
The register is now set to the new value. To verify the new settings, click Reread all. See
the following section for register descriptions.
3.4 Register Descriptions
Table 9: Sensor control registers, address 0 to 63
REG
Decimal
Value
REG
Hexadecimal
Value
Read (R) /
Write (W)
or Command
(C)
Description
0
0
R/W
Data EEPROM
1
1
W
LSB address EEPROM
2
2
W
MSB address and OP-Code
EEPROM
3
3
C
Command SEND_PROM, content of
registers 0 – 2 are sent to the
EEPROM
4
4
C/R
Command RELOAD of the registers
/ Status register has 3 internal states
5
5
R/W
Status register 4 internal states
6
6
R/W
Mode register 0 , adjust camera
modes
7
7
R/W
Mode register 1 , adjust camera
modes
8
8
W
LSB DAC
9
9
W
MSB DAC
Содержание 1M28-SA
Страница 4: ...4 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...
Страница 18: ...18 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...
Страница 28: ...28 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...
Страница 44: ...44 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...
Страница 48: ...48 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...
Страница 52: ...52 PRELIMINARY 1M28 and 1M75 User s Manual 03 32 00525 03 DALSA ...