4. Operating notes
A sensor that is integrated in the backwater closure responds to misting with water and closes the screw cap of the backwater closure with a shaft
that is operated by an electric motor. Even in the event of a power outage (e.g. thunderstorm), all safety functions are ensured for several days with an
integrated emergency power supply (battery).
In addition to the visual alarm, the Stausafe also has an audible alarm. Removing the water protection plug (10) can increase the volume of the
internal alarm.
Removing the plug will reduce the protection against water ingress into the electronics housing to IP 54!
Note:
There is an additional option to connect an external alarm to the potential-free contact. In the event of a malfunction of any kind, the audible alarm
will sound in 20 second intervals.
brown
black
white
21
20
10
13
12
11
19
5
8
m
Power
mmm
Battery
m
Closed
m
Error Sensor
m
Error Motor
1. Operating closure
2. Emergency closure
3. Cover screw connection
4. Manual locking
5. Connecting cable
6. Ductwork
7. Electronics box protection type IP64
8. Power connector for 230 V/50 Hz
9. Multi-function button
10. Water protection plug alarm
11. Water protection plug multi-function button
12. Connection (GLT)
13. Audible warning alarm
14. Sensor
15. Check plug
16. Connector
17. Electronics cover
18. Installation bushing
19. Battery
20. Transformer
21. Battery connector
22. Protection cover
Figure 4.1: Installation situation
Cover
Floating floor
Concrete
Ground
Shaft
6
4
3
22
2
1
16
18
15
14
17
12
11
10
13
8
5
9
7
- 18 -