manualshive.com logo in svg
background image

1

2 (GND)

4

6

8

10

12

14

16

18

3

5

7

9

11

13

15

17 (GND)

Contact IN Cameras (M)

Pin

Assignment

Standard Function

1

Contact 1

Camera 1 - Start recording

3

Contact 3

Camera 3 - Start recording

4

Contact 2

Camera 2 - Start recording

5

Contact 5

Camera 5 - Start recording

6

Contact 4

Camera 4 - Start recording

7

Contact 7

Camera 7 - Start recording

8

Contact 6

Camera 6 - Start recording

9

Contact 9

Camera 9 - Start recording

10

Contact 8

Camera 8 - Start recording

11

Contact 11

Camera 11 - Start recording

12

Contact 10

Camera 10 - Start recording

13

Contact 13

Camera 13 - Start recording

14

Contact 12

Camera 12 - Start recording

15

Contact 15

Camera 15 - Start recording

16

Contact 14

Camera 14 - Start recording

18

Contact 16

Camera 16 - Start recording

Relais OUT (N)

Pin

Assignment

Triggering Event

Type

1 + 4

Relay 1

Recorder in alarm state

Normally closed

3 + 6

Relay 2

None

Normally closed

5 + 8

Relay 3

System error

Normally openr

7 + 10

Relay 4

None

Normally closed

9 + 12

Relay 5

Mehr than 80 % of the hold-up 

tracks occupied

Normally closed

Contact IN Global (O)

1

2 (GND)

4

6

8

10

12

14

16

18

3

5

7

9

11

13

15

17 (GND)

Pin

Assignment Standard Function

11

Contact 17

Global 1 - Shutdown recorder

13

Contact 19

Global 3

14

Contact 18

Global 2

15

Contact 21

Global 5

16

Contact 20

Global 4

18

Contact 22

Global 6

Serial Interface COM 3- COM 6 (S)

Serial Interface COM 1 (S)

Audio IN (P / Q)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Pin

Assign. Function

1

COM 3

RxD (Receive Data)

2

COM 3

RTS (Request to Send)

3

COM 3

TxD (Transmit Data)

4

COM 3

CTS (Clear to Send)

6

COM 4

RxD (Receive Data)

7

COM 4

RTS (Request to Send)

8

COM 4

TxD (Transmit Data)

9

COM 4

CTS (Clear to Send)

Pin

Assign. Function

11

COM 5

RxD (Receive Data)

12

COM 5

RTS (Request to Send)

13

COM 5

TxD (Transmit Data)

14

COM 5

CTS (Clear to Send)

16

COM 6

RxD (Receive Data)

17

COM 6

RTS (Request to Send)

18

COM 6

TxD (Transmit Data)

19

COM 6

CTS (Clear to Send)

Pin

Assignment

1

Audio 1 / 9

2

Audio 2 / 10

3

Audio 3 / 11

4

Audio 4 / 12

5

Audio 5 / 13

6

Audio 6 / 14

7

Audio 7 / 15

8

Audio 8 / 16

Pin

Assignment

9

GND 1 / 9

10

GND 2 / 10

11

GND 3 / 11

12

GND 4 / 12

13

GND 5 / 13

14

GND 6 / 14

15

GND 7+8 / 15+16

Pin

Assignment Function

1

RS485 / 1

RX+

2

RS485 / 1

RX-

3

RS485 / 2

RX+

4

RS485 / 2

RX-

1

2

3

4

1

2

4

6

8

10

12

14

16

18

3

5

7

9

11

13

15

17

20

19

(GND)

(GND)

(GND)

(GND)

Connections

7

Saf
ety

H

DD Moun

ting

Moun

ting

Login

C

onnec

tions

Dimensions

Содержание SMatrix DMX2400

Страница 1: ...Dallmeier DMX 2400 Commissioning 003037 1 1 1 2014 03 13 English...

Страница 2: ...ty 2 Safety Instructions 3 HDD Mounting 4 Mounting 5 Connections 6 Login 8 Dimensions 10 Validity This documentation applies to the audio and video recorder DMX 2400 It has been produced on basis of s...

Страница 3: ...tions damages and data loss and can result in loss of warranty Documentation Carefully and completely read the documents included in delivery Always observe the contained instructions notes and warnin...

Страница 4: ...rive must be equipped with four 3 5 hard disk drives Raid 6 at least Note that all mounted hard disk drives must be tested and released for mounting by Dallmeier HDD whitelist in the Partner Forum may...

Страница 5: ...e guidances show to the internal side Ensure proper ambient conditions Exclusively use the 19 installation rails provided by Dallmeier Shorten the installation guidances predetermined breaking point a...

Страница 6: ...wer Supply Unit 2 L Not Active IEC C14 socket 115 230V AC 5 50 60Hz optional Weidm ller 2 pins C Serial Interface COM 1 M Contact IN Cameras 1 16 2x Weidm ller 2 Pins RS485 for Dallmeier PTZ dome came...

Страница 7: ...12 14 16 18 3 5 7 9 11 13 15 17 GND Pin Assignment Standard Function 11 Contact 17 Global 1 Shutdown recorder 13 Contact 19 Global 3 14 Contact 18 Global 2 15 Contact 21 Global 5 16 Contact 20 Global...

Страница 8: ...ition of the passwords and the network parameters is necessary for remote access e g PView 7 Left click the background The Recorder login dialogue is displayed Commissioning Connect the recorder and r...

Страница 9: ...inistrator group are valid Note that the definition of the passwords and the network parameters is necessary for remote access e g PView 7 Observe the PService documentations Start the software PServi...

Страница 10: ...Dimensions 10 www dallmeier com Housing 19 Rail 19 Holder 40 mm 1 6 22 mm 0 9 43 mm 1 7 35 mm 1 4 645 mm 25 4 445 mm 17 5 442 mm 17 4 533 mm 21 133 mm 5 3 483 mm 19 0 32 mm 1 2 50 mm 2 0...

Страница 11: ...11 Notes Safety HDD Mounting Mounting Login Connections Dimensions...

Страница 12: ...All rights reserved in the event of the grant of a patent utility model or design We reserve the right to make technical modifications The manufacturer accepts no liability for damage to property or p...

Отзывы: