background image

Only use the unit if it is technically in proper working condition and for the intended purpose while keeping safety and potential 
dangers in mind.
Qualified Personnel 
The installation, mounting, connection, commissioning and configuration of the unit may only be carried out by qualified 
personnel. This also applies to the maintenance, testing and repair, whereat the regulations of the DIN VDE 0701 series of 
standards (repair, modification and inspection of electrical appliances) must be followed.
Regulations
The use of video and audio surveillance systems is, in general, strictly regulated. Inform yourself about the currently valid 
laws and regulations regarding data, worker and environmental protection before using the unit and ensure compliance with 
them.
System Components
Only use internal components that have been tested and approved by Dallmeier. Inappropriate internal components can 
cause malfunctions, damages and data loss and can result in the loss of warranty.
Modifications
Do not make any modifications to the hardware or software that has not been tested and approved by Dallmeier.
Inappropriate modifications can cause malfunctions, damages and data loss and can result in the loss of warranty.
Documentation
Read the documents included in the delivery carefully and thoroughly. Always observe the contained instructions, notes and 
warnings.
Condensation Water
If the unit is brought from a cold to a warm environment, resulting condensation water can cause malfunctions and damages. 
In this case, wait (up to 8 hours) until the unit has reached room temperature before commissioning.
Earthing & Equipotential Bonding
For the safety of persons (protection against dangerous contact voltages) and devices (protection against overvoltages) and 
the immunity of information and communication technology equipment to electromagnetic interferences (EMI), all protec-
tive measures, which are specified by the currently valid DIN, VDE and ISO standards and which provide for a standard-com-
pliant earthing and a correct equipotential bonding of electrical and electronic devices, are mandatory and must be fulfilled 
by all means.
Lightning Storms
To avoid damage to the unit by electrical surge during lightning storms, unplug the unit from the mains power supply (pull 
out the power plug). This is also recommended, when the unit has been unused for a long period of time.
Operating Conditions
Unfavourable operating conditions can shorten the life of the unit and can cause malfunctions, damages and data loss and 
can result in the loss of warranty. Observe the specifications given in the technical data, the operating condition requirements 
and the maintenance instructions.
Shocks
Shocks can cause malfunctions and damages. The unit may not be moved while in operation.
Foreign Bodies
If objects or liquids get into the unit, immediately disconnect it from the power supply (pull out the power plug).
Contact the sales partner responsible for your area.
Burnt Smell
If you notice burnt smell or a formation of smoke coming from the unit, immediately disconnect it from the power supply 
(pull out the power plug). Contact the sales partner responsible for your area.
Opening
The housing of the unit may only be opened by qualified personnel for commissioning, inspection, maintenance and repair.
Disposal
Do not dispose waste electrical and electronic equipment into the household trash. Disconnect the unit from the power sup-
ply. Remove all connected devices. Return the unit to your respective sales partner.

Safety Instructions

                

 3

H

DD Moun

ting

Moun

ting

Saf
ety

Requir

emen

ts

DL

S 1600

Local L

ogin

Dimensions

D

M

S 2400

Remote L

ogin

Indica

tors

Содержание DMS 2400

Страница 1: ...PRELOADED English Commissioning 003864 Rev 1 0 5 2014 03 13 Appliance DMS 2400 DLS 1600...

Страница 2: ...dicates a hazardous situation which if not avoided will result in death or serious injury Warning WARNING indicates a hazardous situation which if not avoided could result in death or serious injury C...

Страница 3: ...protection against overvoltages and the immunity of information and communication technology equipment to electromagnetic interferences EMI all protec tive measures which are specified by the current...

Страница 4: ...otection of Electronic Computer Data Processing Equipment ANSI NFPA 75 Secured room Risk of manipulation and sabotage A stand alone installation should be operated in secured rooms with restricted acc...

Страница 5: ...be mounted connected and commissioned directly Devices that have been ordered without hard disk drives must be equipped with one 3 5 hard disk drive at least Note that all mounted hard disk drives mu...

Страница 6: ...he device into the 19 rack Observe the instructions of the rack manufacturer Ensure 4 10cm of free space at the front rear and right side Connect the device as described on the following pages Commiss...

Страница 7: ...7 Dimensions 445mm 133mm 425mm 133mm 95mm 38mm 427mm 431mm 424mm HDD Mounting Mounting Safety Requirements DLS 1600 Local Login Dimensions DMS 2400 Remote Login Indicators...

Страница 8: ...3 5mm Phone Jack 3 not active C Contact IN global 1 6 Weidm ller 8 pins only for switch push button dry contact O Microphone IN 3 5mm phone jack red 4 3kOhm 2 828Vpp D Mouse PS 2 green P Audio OUT 3 5...

Страница 9: ...2 pol Pin Assignment 1 12V DC 2 GND Pin Assignment 7 Contact 6 8 GND Pin Assignment 1 GND 2 Contact 1 3 Contact 2 Pin Assignment 4 Contact 3 5 Contact 4 6 Contact 5 Pin Assignment 7 Contact 6 8 GND Pi...

Страница 10: ...ptional L Microphone IN 3 5mm phone jack red 4 3kOhm 2 828Vpp C Contact IN global 1 6 Weidm ller 8 pins only for switch push button dry contact M Video OUT 1 2 BNC 75Ohm 1Vpp CVBS video only no config...

Страница 11: ...Audio 1 2 Audio 2 3 Audio 3 4 Audio 4 5 Audio 5 Pin Assignment 6 Audio 6 7 Audio 7 8 Audio 8 9 GND 1 10 GND 2 Pin Assignment 11 GND 3 12 GND 4 13 GND 5 14 GND 6 15 GND 7 8 Audio IN Q D SUB 15 pol with...

Страница 12: ...te In the initial state cameras are displayed with wildcards on the user interface Login In the initial state it is possible to login without a password The rights of the Administrator group are valid...

Страница 13: ...information is displayed The password input field is displayed Login In the initial state it is possible to login remote using the serial number as password The rights of the Administrator group are v...

Страница 14: ...ra failures or hard disk faults F USB interface USB 2 0 type A G HDD DVD RW drives Behind the flap H Display Shows information and status messages Indicators Information and status messages are output...

Страница 15: ...15 Notes HDD Mounting Mounting Safety Requirements DLS 1600 Local Login Dimensions DMS 2400 Remote Login Indicators...

Страница 16: ...the grant of a patent utility model or design We reserve the right to make technical modifications The manufacturer accepts no liability for damage to property or pecuniary damages arising due to mino...

Отзывы: