47
¾
Sensitivity
:
Select sensitivity of motion detection or video shelter. Option including: Highest, High,
Medium, Low, Lowest.
¾
Area Setup
:
Alarm area should also be set to activate motion detection or video shelter though such function
was selected.
In area setup interface, full screen is the default alarm area. In
Ⅰ
type 4 channel model,
Ⅱ
type model and
Ⅲ
type model, use direction key to move cursor, press
to cancel chose area, and press
to
recover chose area. In
Ⅰ
type 16 channel model, use direction key to move cursor, press number “2” key to
cancel chose area, and press number “1” key to recover chose area.
¾
Rec. CH
:
When alarm activated, relevant channel can be selected to record if recording period has been
setup in “Alarm Schedule” menu.
¾
Spot Camera:
The channel, which motion happened in, can be selected to display as full screen.
¾
Alarm Out
:
Activate alarm out or not.
¾
Schedule
:
Enter “Alarm Schedule” interface to setup alarm period in which system will activate relevant
disposal mode such as buzzer alarm, related channel full-screen display, alarm output, relevant channel
recording if alarm has triggered. Alarm schedule setting is the same as schedule recording setting, please
refer
Schedule Recording
section.
In the course of setting up the parameters, if the parameters needed to be set the same in all channels, you can
select ‘
ALL
’ after finishing the setup of parameters of one channel. The system will prompt a dialog box.
When pressing ‘
OK
’, parameters setup for all channels will be achieved.
Note: “Sheltering” and “Video Loss” settings please refer to “Motion” setup.
Alarm Elimination
Click
icon on the status bar to eliminate beep alarm if the alarm is activating.
Section 9
Playback/Backup
Playback
Press
,
or
in front panel to enter the search interface as show in Fig. 41.