Electrical wiring
Wiring must comply with local regulations and standards in force and meet the electrical require-
ments of the detector
DAX 3F-I
.
Dalemans recommends the use of colour coded cable. The acceptable cross sectional area of the
cable is 1.5 to 2.5 mm² depending on the type of sensor used and the distance between the detec
-
tor and the control unit. For more information about the cross sectional area of the cable and the
maximum cable length, please refer to the instruction manual of the control unit. The overall cable
diameter must be within the range given in figure 6 below. Cable gland must be sufficiently
tightened on the cable to ensure a good sealing.
Junction box
Mounting bracket
Other size
upon request
M8 hexagonal nut
Sealing serrated
lock washer
Washer
M8x16 screw
Figure 6 : Cable stripping
Figure 5 : Mounting for external brackets
6 mm
-
12 mm
15 mm
100 mm
8 mm MAX
1.5 - 2.5 mm²