RESPONSIBILITIES – WARRANTY 

 
 

 

The fitter commits himself to comply with EC standards and with the installation instructions. 

The installation must be carried out by qualified personnel. 

All our products are tested and inspected before shipping. 

 

 

These instructions must be read carefully by any person who has or will have the responsibility for the 
installation, the use and/or the maintenance of this equipment. The warranty provided by DALEMANS will be 
voided if installation, use and maintenance of this equipment are not in accordance with the instructions 
given in this manual. 

By respecting these instructions you guarantee the correct operation of the apparatus. Should you require 
any further information about the use or the maintenance of this product, do not hesitate to contact 
Dalemans PRIOR to carrying out installation works. 

Each apparatus must be installed, operated and maintained according to the instructions, the warnings and 
the operational limits detailed in this manual. 

Use only DALEMANS original parts when you assume the maintenance of this product as specified in this 
manual. The use of non-Dalemans spare parts may seriously impair the performances of the apparatus. 
Repair or maintenance attempts carried out without observing the procedures described in this manual or 
without the assistance of our after-sales service may prevent the equipment from working  properly and, 
consequently, from ensuring the safety of the occupants of the building and of the plants. 

This device must be installed in a dry and clean place. Install a protection (housing) to avoid possible water 
or poisoning agent projections. 

Do not hesitate to contact us for any additional information about the use or the maintenance of this product. 
Dalemans cannot be liable for direct or indirect damages arising out of the non-observance of its instructions. 

Plans, schematics and information of this handbook are the property of Dalemans and could not be 
reproduced or used without its prior agreement. 

 

 

ENVIRONMENT 

 

 

The crossed-out wheelie bin logo on this product indicates that you are held to respect 
the regulation in force on the collection and recycling of waste electrical and electronic 
equipments. 

These provisions are intended to preserve the natural resources used for manufacturing 
this product and to avoid the dispersion of substances potentially harmful for the 
environment and human health. 

Therefore, to dispose of your end-of-life product, you MUST hand it over to a designated 
collection point for the recycling of electrical and electronic equipments. For further 
information about the collection points in your area, contact your local city office. 

 

 
 
 
 
 
 

Содержание DAT 420

Страница 1: ...TOXIC GAS AND OXYGEN DETECTOR DAT 420 CALIBRATION MANUAL...

Страница 2: ...ntenance attempts carried out without observing the procedures described in this manual or without the assistance of our after sales service may prevent the equipment from working properly and consequ...

Страница 3: ...DAT420_MAN02_EN docx V1R1 ii DAT 420 Document DAT420_MAN02_EN DOCX Version V1R1 Date 11 07 2011...

Страница 4: ...1 7 TROUBLESHOOTING 12 8 ACCESSORIES AND SPARE PARTS 12 ILLUSTRATIONS AND TABLES Figure 1 Exploded view of the detector 3 Figure 2 Calibration mask 4 Figure 3 Measurement probes 4 Figure 4 Power suppl...

Страница 5: ...invalidate the essential safety requirements of the whole plant No additional drilling is allowed on the junction box The existing openings cannot be enlarged No additional terminal can be installed o...

Страница 6: ...time T90 45 sec Expected operating life span 2 years Supply voltage 15 30 Vdc Supply current Max 30 mA Storage temperature 40 C to 80 C Operating conditions Temperature range Ambient humidity Intermi...

Страница 7: ...emans Figure 1 Exploded view of the detector FLAMEPROOF d STOPPER PLUG SINTERED METAL FILTER SENSING HEAD BASE FPH01 STAINLESS STEEL FLAMEPROOF d JUNCTION BOX PRE00000033 BOI00000188 MEC00000010 VISVI...

Страница 8: ...or PVC with approximately 4 mm interior diameter TUB00000009 A measurement probes set fitted with a connector with a pitch of 2 mm ACC00000012 see figure below A digital voltmeter A precision insulat...

Страница 9: ...e to use the OctoPRO calibration unit to simulate the 4 20 mA current loop Contact Dalemans for further information The 4 20 mA current loop may also be simulated as follows 1 Power the detector from...

Страница 10: ...ation consists of creating a calibration atmosphere around the sensing head by injecting a reference gas To avoid contamination of the calibration gas by the ambient atmosphere or air draughts always...

Страница 11: ...essible through the slot in the side of the calibration mask Tighten down the locking screw on the calibration mask 6 Using the measurement probes Figure 3 Page 4 connect the voltmeter across the conn...

Страница 12: ...to 3 minutes 5 On the transmitter adjust the ZERO potentiometer figure below to obtain 40 mV 0 1 mV on the voltmeter Figure 7 Calibration for toxic gases 6 Stop applying nitrogen and wait until the 40...

Страница 13: ...300 20 00 200 00 13 60 136 00 8 80 88 00 4 96 49 60 500 20 00 200 00 12 00 120 00 5 60 56 00 1000 20 00 200 00 7 20 72 00 2000 10 40 104 00 9 On the control unit PLC to which the detector is connecte...

Страница 14: ...n remove the calibration mask and leave the sensor in free air for 5 to 10 minutes so that the 40 200 mV output signal stabilises completely 8 Adjust the GAIN potentiometer figure below to obtain a re...

Страница 15: ...tor 0 500 4 Diborane B2H6 0 300 2 Fluorine F2 Calibration with Cl2 generator Hydrazine N2H4 Gaseous permeation 5 Hydrochloric acid HCl 0 300 3 Hydrocyanic acid HCN 0 250 1 Hydrofluoric acid HF 0 500 5...

Страница 16: ...OUT00000089 Hose PVC 4 mm TUB00000009 Key for locking screw 1 5 mm hex key OUT00000115 Measurement probes Pitch 2 mm ACC00000012 Spanner for the base of the sensing head 30 mm OUT00000114 Spanner for...

Страница 17: ...DALEMANS s a Rue Jules M lotte 27 B 4350 Remicourt Tel 32 0 19 54 52 36 Fax 32 0 19 54 55 34 info dalemans com www dalemans com...

Отзывы: