MAXICUT
Page 41
Change cylinders for hydraulic pull
By replacing the cylinders with hydraulic pull. MUST keep the machine collapsed and
lowered without strain on the pull.
Fig. 28
1.
The pull is supported.
2.
The pressure is taken off the cylin-
ders (A).
3.
The hoses are removed.
4.
Cotter pins and nails are removed,
and then the cylinder is free.
5.
The new or repaired cylinder is in-
stalled. Remember to secure the
nail in the nail stop and secure the
nails with cotter pins.
6.
The hoses are installed. After in-
stallation, ensure that there is no
risk of tearing or clamping the
hoses.
After installation, activate the cylinders again. The cylinders are activated both ways
and are fully sealed in both outer positions. This must be done in order to ventilate
the system with the cylinder.
There must never be persons within the operating radius.
A