56
ALArMS
DiSpLAy
expLAnAtiOn
SOLutiOn
Indicates the presence of an alarm.
on: indicates the presence of an alarm
off: indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset by pressing key 3 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
FuMeS FAiLure
Fault correlated to the flue gas
exhaust motor.
The restoration operations must be carried out by an authorised
technician.
FuMeS prOBe
Fault correlated to the fumes probe.
The restoration operations must be carried out by an authorised
technician.
ALArM
FuMeS OverteMper-
Ature
The flue gas temperature has
exceeded 310°C
Check pellet flow (see “Pellet feed adjustment”).
Check that the machine is clean, including the flue route.
Do not rest cloths on the machine.
other restoration operations must be carried out by an authorised
technician.
cLeAn
cHeck-up 1 - 2
(1= At StArtup)
(2= At WOrk)
The combustion chamber or burn pot
bottom are dirty.
The door is not closed correctly.
The ash drawer is not closed
correctly.
The depression sensor is faulty.
The flue exhaust pipe is blocked.
Incorrect installation
Make sure the holes at the burn pot bottom are completely free.
Check cleanliness of the fumes pipe, of the sensor in the primary
air channel and the combustion chamber.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
other restoration operations must be carried out by an authorised
technician.
Depr ALArM
The mechanical depression sensor
has tripped
Contact after-sales centre
nO
ignitiOn
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Incorrect installation
Check for the presence of pellets in the feed-box.
adjust pellet flow (see “Pellet feed adjustment”).
Check the procedures described in the “Ignition” chapter.
other restoration operations must be carried out by an authorised
technician.
BLAck-Out nO ign.
No current during the ignition phase.
Take the stove to oFF conditions using key 1 and repeat the
procedure described in the "Ignition" chapter.
other restoration operations must be carried out by an authorised
technician.
nO peLLetS
In the work phase, the t° of the flue
gases has dropped below factory
parameters
Check for the presence of pellets in the feed-box.
regulate the pellet flow.
other restoration operations must be carried out by an authorised
technician.
cOOLing StAnD-By
attempt to release the alarm with
stove still in cooling mode.
Every time the stove displays one of the alarms listed above it will
switch-off automatically.
The stove will block any release attempt during this phase,
showing the alarm itself and aTTE alternately on the display.
The alarm can be reset by pressing key 1 for 3 seconds only if the
fumes motor has stopped and if 15 minutes have passed from
displaying the same alarm.
Depr SenSOr
DAMAge
Component disconnected or faulty
Contact after-sales assistance
Auger cOntrOL
ALArM
anomalous functioning
of pellet feeding
Contact after-sales assistance