46
tHe DiSpLAy DeScriptiOn OF cOntrOLS AnD SyMBOLS
oN/oFF
BUTToN
DISPLaY oF VarIoUS
TEXT MESSagES
DISPLaY
oF PoWEr
TEMPEraTUrE SETTINg
oPEraTIoN PoWEr
aDJUSTMENT
DiSpLAy icOnS key
Indicates the presence of an alarm.
on: indicates the presence of an alarm
off: indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
It indicates weekly programming functioning
Indicator on = Weekly programming active
Indicator off = Weekly programming not active
Indicates the environment temperature status
off = the T° read by the probe is over the set temperature set
on = the T° read by the probe is below the set temperature set
Indicates the stby function
off = Stby deactivated
on = Stby activated
Ign-plug
off = ign-plug active
on = ign-plug deactivated
Flashing = Ignition phase
additional external thermostat input status
off = open contact
on = closed contact
It indicates functioning of the fumes motor.
off = fumes motor not working
on = fumes motor working
Flashing = breakdown
It indicates the communication between remote control and
stove. Every time a key is pressed on the remote control the
indicator must switch on. If the indicator is always on it indicates
that the communication between remote control and stove is
blocked.
*
1
It indicates functioning of the tangential fan
off = not working
on = working
Not used
2
Not used
additional ducted thermostat input status:
on: closed contact (to be reached)
Flashing: the motor is running at minimum, in modulation
mode (input=open)
It indicates functioning of the pellet feed motor.
off = pellet feed motor deactivated
on = pellet feed motor active.