Diagnostics & Troubleshooting
34
PLR615X Self-Test Mode
The PLR self-test mode is used to test internal systems and I/O ports. While in self-test
mode, the PLR tests for correct operation and shows a pass/fail status on the four status
If any failures are detected, error codes are displayed to define the source of the failure.
The self-test connections are shown in
ProLink5 SATA
cable loopback
ProLink6 coax
cable loopback
Power jack
Figure 33:
PLR615X Self-Test
To put the PLR615X into self-test mode, follow these steps:
1.
Loop the SATA cable from Port A to Port B on the ProLink5 jacks.
2.
Connect a coax cable from coax Channel 0 to coax Channel 3 and a second cable
from coax Channel 1 to coax Channel 2.
3.
Disconnect the power and then reconnect the power.
During the self-test, the
HB
LED toggles once per second. The four status LEDs light up for
three seconds before initiating a repeating test-in-progress pattern. This alternating chase
Содержание PROLINK ROUTER 605 Series