Diagnostics & Troubleshooting
31
Code
Description
F
0
A
Temperature error
F
0
B
ID error
F
0
C
Serial flash error
F
0
D
EPLD error
F
0
E
EPLD oscillator error
F
0
F
EEPROM error
F
1
0
Firmware error
F
1
1
ProLink5 configuration error
F
1
2
7-Segment display error
F
1
3
VIN voltage error
F
x
x
Other self-test error
PLR615X Status LEDs
Status information is shown on the four status LEDs labeled
ERR
,
0
,
1
, and
2
. To the left
of the status LEDs, there is a heartbeat LED labeled
HB
. The
HB
indicator LED toggles at
a rate of once per second when the PLR is in normal operation or self-test mode and
toggles at a rate of 10 times per second when the PLR is in bootstrap mode. Refer to
.
ProLink6 coax Port A
ProLink6 coax Port B
ProLink5 SATA Port B
ProLink5 SATA Port A
Status LEDs
Power jack
Ch 0 Ch 1 Ch 2 Ch 3
Figure 30:
PLR615X
Содержание PROLINK ROUTER 605 Series