Electrical Installation
29
Using the Quick Connect and less then the 10 foot cable
1.
Run ¾" conduit from the sensor location to the Quick connect Temp Sensor input at the back
of the first display. The cable must be routed through ¾" metal conduit that should be earth-
grounded to protect the sensor and controller from lightning damage.
2.
Disconnect the CAN temp sensor cable from the temperature sensor terminal block in the
CAN temp sensor housing. (0A-1241-4017)
3.
Cut the cable to desired length and reattach to the temperature sensor terminal black in the
CAN temp sensor housing as follows:
Wire Color Terminal Block (TB1)
Red
+5V CAN
Green
CANH
White
CANL
Black
GND CAN
*Note:
Do not terminate shield at this point.
Figure 32:
CAN Temp Sensor Wiring