Quick Guide: Digit Display Installation with FLR 1500 Control Kit
4 of 5
PO Box 5128 201 Daktronics Dr Brookings SD 57006-5128
tel 605-697-4036 or 800-325-8766 fax 605-697-4700
www.daktronics.com
DD1399086 Rev 2
12 April 2010
Hand-Held Controller Use
After power and signal installation, set up the hand-held controller by using the following steps.
Hand-Held Controller Setup
Note
: These steps only need to be performed the first time the controller is powered up.
LCD Screen
Action
CURRENT FUNCTION
GAS PRICE
•
For Indoor Installations Only:
Plug the wall pack transformer into a
120 V AC power outlet and connect it to the hand-held controller.
•
This display appears briefly.
CHANGE FUNCTION?
PRESS SET FUNCT
•
This message appears next on the screen.
•
If “GAS PRICE” was shown on the bottom line of the LCD during
startup, do nothing. The controller will automatically default to previous
Gas Price settings.
•
If a function other than “GAS PRICE” was shown on the bottom line of
the LCD during startup, press the
[Set Function]
key while the second
LCD prompt is displayed.
SELECT FUNCTION
GAS PRICE
↓↑
•
Press the arrow up or down keys<
↑
↓
> until the gas price option is
shown. Press the
[Enter]
key to accept.
To set petroleum prices, follow these steps:
LCD Screen
Action
LINE PRICE
1
↓
$1.23 9/10
<EDIT> TO MODIFY
1
↓
$1.23 9/10
•
The display will toggle between these two screens.
•
Press the up or down arrow keys
<
↑
↓
> to scroll through the current
setting for any of the lines on the display.
•
Press the
[Enter/Edit]
key to modify any of the line settings.
•
Press any of the number keys to edit the price value for this line.
•
Press
[Enter]
to accept the new value or press
[Clear]
to abort the
changes.
•
Press
[Update Display]
to send the values to the display.