Electrical Installation
4-2
WARNING:
It is critical that the scoreboard circuit be fused at 15 A, and that all
conductors used must be designed to pass a 15 A current in normal operation. Failure
to meet wiring and overcurrent protection device requirements is a violation of the
National Electrical Code
®
and will void the scoreboard warranty.
All power conductors are 14 AWG, except where 18 AWG wiring is called out on
the schematic. All signal conductors are 18 AWG.
Refer to the outdoor scoreboard schematics listed at the beginning of this section and
to the table in
Section 2
to determine circuit specifications and maximum power
requirements for the models described in this manual.
Grounding
Note
: Displays MUST be grounded according to the provisions outlined in Article
250 of the National Electrical Code and according to the specifications in this
manual. Daktronics recommends a resistance-to-ground of 10 ohms or less.
The electrical contractor performing the electrical installation can verify ground
resistance. Daktronics Sales and Service personnel can also provide this service.
The display system
must
be connected to an earth electrode installed at the display.
Proper grounding is necessary for reliable equipment operation. It also protects the
equipment from damaging electrical disturbances and lightning.
Note:
The display must be properly grounded or the warranty will be void.
Refer to
the schematics listed at the beginning of this section for information about ground
wire connection. The connection is illustrated in the “Pwr In” detail on each of the
schematics.
The material for an earth-ground electrode differs from region to region and may
vary according to conditions present at the site. Consult the National Electrical Code
and any local electrical codes that may apply. The support structure of the display
cannot be used as an earth-ground electrode. The support is generally embedded in
concrete, and if it is in earth, the steel is usually primed or it corrodes, making it a
poor ground in either case.
Power Installation
There are two considerations for power installation: installation with ground and
neutral conductors provided, and installation with only a neutral conductor provided.
These two power installations differ slightly, as described in the following
paragraphs:
Installation with Ground and Neutral Conductors Provided
For this type of installation, the power circuit
must
contain an isolated earth-ground
conductor. In this circumstance,
do not
connect neutral to ground at the disconnect or
at the display.
Содержание DistaView BA-1518-31
Страница 4: ......
Страница 18: ......
Страница 26: ......
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 39: ......
Страница 40: ......
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 49: ......
Страница 50: ......
Страница 51: ...Eyebolts B 1 Eyebolts ED 7244...
Страница 52: ......
Страница 55: ...Appendix C C 1...
Страница 56: ......