Parts Replacement 

19

Section 5:  Parts Replacement

Following is information needed to obtain new parts from Daktronics and how to install them in the display. 

5.1  Replacement Parts List

The following formats may be found on various Daktronics drawings. These 
part numbers can be used when requesting replacement parts from Daktronics 
Customer Service.

Most components within this display carry a label that lists the part number of 
the unit. If as assembly is not listed in the Replacement Parts List below, use the 
label, as shown in 

Figure 15

, to order a replacement. The part number in bold.

0P-1127-0024

SN:  

     2465

02/19/12 Rev. 1

Figure 15: 

Parts Label

Description

Daktronics Part No.

Temperature Sensor

0A-1151-0012

Light and Temperature Sensor

0P-1247-0008

Protocol plug (Protocol-4)

0A-1279-0089

Transformer

T-1072

24 Volt, 150 W DC Power Supply

A-1720

Signal surge suppression board

0P-1110-0011

Driver, 4 Column

0P-1192-0068

DM-100 Controller parts

DM-100 handheld controller

0A-1196-0088

Junction box, outdoor, 9-pin D-male

0A-1196-0093

Junction box, indoor, 9-pin D, male

0A-1196-0099

DM-100 Insert Time & Temp/Gas Price

0G-164998

DM-100 outdoor wired installation kit

0A-1279-0087

DM-100 indoor wired installation kit 

0A-1279-0103

Transformer, wall pack (for DM-100)

T-1118

Cable, serial, DB9 male to DB9 female

W-1267

Digits and Accessories

Digit, 10” red, 7-segment

0A-1192-5120

Digit, 10” amber, 7-segment

0A-1192-5220

Digit, 13” red, 7-segment

0A-1192-5130

Digit, 13” amber, 7-segment

0A-1192-5230

Digit, 18”, red, 7-segment

0A-1192-5140

Digit, 18”, amber, 7-segment

0A-1192-5240

Digit segment, 24” red, vertical

0A-1192-5150

Digit segment, 24” red horizontal

0A-1192-5151

Digit segment, 24” amber, vertical

0A-1192-5250

Digit segment, 24” amber horizontal

0A-1192-5251

Indicator, 1” red (10” and 13” displays)

0A-1611-5133

Indicator, 1” amber (10” and 13” displays)

0A-1611-5233

Indicator, 2” red (18” and 24” displays)

0A-1611-5134

Indicator, 2” amber (18” and 24” displays)

0A-1611-5234

Содержание DataTime DF-1012

Страница 1: ...1 201 Daktronics Drive PO Box 5128 Brookings SD 57006 tel 800 843 5843 fax 605 697 4700 www daktronics com DataTime DF 1012 Time Temperature Display Installation and Operation Manual DD2563927 Rev 02...

Страница 2: ...rrors or omissions No part of this book covered by the copyrights hereon may be reproduced or copied in any form or by any means graphic electronic or mechanical including photocopying taping or infor...

Страница 3: ...ounding Connections 7 3 4 Power Installation 8 Installation With Ground and Neutral Conductors Provided 8 Installation With Only A Neutral Conductor Provided 8 3 5 Lightning Protection 8 3 6 Signal Co...

Страница 4: ...Temperature Display Setup 28 Menu Items 29 Daylight Savings Setting 29 Set Time 29 Set Date 30 Degrees F Temperature Offset 30 Set Degrees C Temperature Offset 31 Time Temperature Format Hold Settings...

Страница 5: ...ervice please have this information available to ensure that a request is serviced as quickly as possible 1 2 Product Overview DataTime Time Temperature displays show temperatures in Fahrenheit or Cel...

Страница 6: ......

Страница 7: ...e DataTime displays are designed for wall or pole mounting every installation is different Actual site demands dictate the appropriate mounting method DataTime DF 1012 models are designed to be insert...

Страница 8: ...erature information Both temperature and light monitoring electronics are located in the sensor housing shown in Figure 2 The Daktronics Controller Area Network CAN Temperature Light Sensor is pre ins...

Страница 9: ...et vertically between the sensor and the influential element Locations that restrict air movement are also unsatisfactory When a display has two faces do not mount the sensor between the faces Connect...

Страница 10: ...eater than the provided 25 foot 7 6 m cable connect a 4 conductor shielded cable from the sensor to TB1 on the display driver board 1 The display s power must be OFF when attaching the internal sensor...

Страница 11: ...al installation 3 2 Power Connections Daktronics DataTime displays have removable or hinged front panels that allow access to the digits cabling and other electronic components DataTime outdoor displa...

Страница 12: ...isolated earth ground conductor In this circumstance do not connect neutral to ground at the disconnect or at the display as this would violate electrical codes and void the warranty Use a disconnect...

Страница 13: ...ated as the host driver which receives its signal directly from the DataMaster controller on its Signal IN terminals It is the only driver that is connected to the photo temperature sensor The Signal...

Страница 14: ...protocol jack J20 3 Route a six conductor 18 AWG shielded signal cable through conduit from the J box to the driver enclosure in the host display Fifty feet 15 2 m of signal wire is provided 4 Connec...

Страница 15: ...need to be connected to the J box and a wall pack transformer will be used for power to the DataMaster controller The distance from the indoor J box to the host driver can be up to 2 000 ft 600 m Ref...

Страница 16: ...ect to the client drivers Refer to Figure 12 and Drawing A 185236 for an illustration of the client host display connection Client drivers receive signal from the host driver on SIGNAL OUT J1 24VDC RA...

Страница 17: ...e of information is shown on the driver s digits The switch is set using a binary address Use the table and the examples in Figure 13 for setting the address Note Some older drivers set the address of...

Страница 18: ......

Страница 19: ...Surge Board Signal Power Input Termination Jacks On 10 and 13 displays all the components are behind one door For 18 and 24 displays the hinged doors swing outward when the two latches on the front di...

Страница 20: ...protocol plug is not connected Protocol plug for host driver only Check addressing of client display Client drivers will continually cycle through the power on self test host driver Make sure address...

Страница 21: ...e case either the wrong address is set or the driver or digit harness is connected incorrectly If no address is set on the host driver it will display E5 and all client drivers will continually cycle...

Страница 22: ......

Страница 23: ...ssion board 0P 1110 0011 Driver 4 Column 0P 1192 0068 DM 100 Controller parts DM 100 handheld controller 0A 1196 0088 Junction box outdoor 9 pin D male 0A 1196 0093 Junction box indoor 9 pin D male 0A...

Страница 24: ...constructed in segments as shown in Figure 16 In this case make repairs by removing only the defective segment Do not attempt to remove individual LEDs To remove a digit segment follow these steps 1...

Страница 25: ...cation of the driver All DataTime displays are front accessible 1 Open the digit panel or display face panel as described in Section 4 1 2 Remove the cover from the driver enclosure 3 Label all cables...

Страница 26: ...in Section 4 1 2 Remove the cover from the driver enclosure 3 Disconnect the power connector from the surge board Release it by squeezing together the locking tabs and pull the connector free Note Whe...

Страница 27: ...ler Refer to Drawings A 938300 for the location of the surge board inside the driver enclosure The surge board is pre wired before the display is shipped Note The surge suppressor must be firmly conne...

Страница 28: ......

Страница 29: ...part fixes the problem send in the failed part within 3 weeks of the ship date a Package the old part in the same shipping materials in which the replacement part arrived b Fill out and attach the en...

Страница 30: ...d be placed in an antistatic bag before boxing Daktronics does not recommend using packing peanuts 4 Enclose your name address phone number the RMA number a clear description of symptoms Shipping Addr...

Страница 31: ...mation for the displays To see more detail on the DM 100 insert refer to drawing A 164998 If an insert is lost or damaged a copy of the insert drawing can be used until a replacement is ordered To sta...

Страница 32: ...on key quickly to enter Function mode If you miss this step unplug the power to the DM 100 controller and start again Note The actual Time Temperature values will not be displayed on the DM 100 LCD be...

Страница 33: ...key to accept Press the down arrow key to select the Enable or Disable Daylight saving time correction If enabled the display time automatically corrects for daylight saving time The default setting...

Страница 34: ...or decrement the Fahrenheit temperature value read from the temperature sensor LED Screen Action MM Current month DD Current day YY Current year last two digits Input the month MM using the number key...

Страница 35: ...ve humidity RH is available on the DM 100 controller but cannot be read using the standard temp light sensor LED Screen Action 00 shows the current degrees Celsius temperature offset Press the Up and...

Страница 36: ...tings The DM 100 controller has an option to set modem settings but this method of communication is not used with standard Time Temp Displays If a modem was used the next screen would require the user...

Страница 37: ...key to toggle through dim settings Automatic The display automatically dims based on the light detected at the display Manual The dimming level is set manually Once set this value remains regardless...

Страница 38: ......

Страница 39: ...work The address is set using an 8 position binary switch For single line signs such as a Time Temp display the address will typically be 1 The address will be displayed each time the display powers u...

Страница 40: ......

Страница 41: ...trol Drawing A 175342 Time Temp Power Signal Hookup Drawing A 938369 Installation Temp Sensor G3 Drawing A 184840 Enclosed Driver 4 Column Reference Drawing A 938300 Host Client Definitions Drawing A...

Страница 42: ......

Страница 43: ...Appendix B Temperature Sensor Mounting 39 Appendix B Temperature Sensor Mounting ED 18601 Temperature Sensor Mounting ED 18601...

Страница 44: ......

Страница 45: ...Appendix C DataTime Quick Installation Reference 41 Appendix C DataTime Quick Installation Reference A 176249 Installation Quick Reference DF 1012 Time Temp Drawing A 176249...

Страница 46: ......

Страница 47: ...Appendix D DataTime Quick Start Reference 43 Appendix D DataTime Quick Start Reference DD2563921 DataTime Time Temperature Quick Start Reference DD2563921...

Страница 48: ......

Страница 49: ...Appendix E Warranty and Limitation of Liability 45 Appendix E Daktronics Warranty and Limitation of Liability SL 02374...

Отзывы: