13.4 Dim
The
MAX II
has a built-in
DIM
feature to manage power more effectively. This
feature has adjustable time durations, until the power of the display is dimmed and
current draw reduced. The timer is constantly reset while the user is making
measurements, and is only activated when the gauge is idle for the duration of time
the
DIM
value is set for. This feature does not override the preset 5 min idle power
off feature in any way. However, if the gauge is turned on, set for a DIM of 120sec,
and then left idle for 5 minutes, the
MAX II
will dim in 2 minutes, then power off in 5
minutes. The procedures for adjusting the
DIM
time are outlined below:
Setting a DIM time
1) Press the
MENU
key once to activate the menu items tab. Press the
MENU
key multiple times to tab right and the
ESC
key multiple times to tab left until
the
DISP
menu is highlighted and displaying the submenu items.
Alternatively, press the
LEFT
and
RIGHT
arrow keys multiple times
using the left button wheel.
2) Use the
UP
and
DOWN
arrow keys multiple times using the left button
wheel to scroll through the sub menu items until
DIM
is highlighted.
3) Press the
LEFT
and
RIGHT
arrow keys multiple times on the right
button wheel to scroll the
DIM
time.
4) Finally, press the
MEAS
key to return to the measurement screen and begin
taking readings.