page 4
MAN#650231:A
Pulls up all values
on speed and speed pulses in odometer
Press Right switch to finish cal and save value
ADJUST
Adjust speed cal while driving
ADJUST
Each press of left switch toggles direction of adjustment, right switch to save and exit
SRV MI
(
SRV KM
)
Sets value of service odometer set when service odometer is reset
OFF
(
OFF
)
Turns off the count down service odometer (default)
500
(
800
)
Sets service to 500 mi or 800 km when resetting service odometer.
….
Service point can be set in 500 mi (800km) increments.
7500
(
12000
)
Sets service to 7500 mi or 12000 km when resetting service odometer.
MAIN
Returns to info menu
TACH
Tachometer gauge menu
ENGINE
Sets number of cylinders from 1-15 (default 12 for use on alternator output)
WARN
Sets RPM warning point (default 5500 RPM)
W 2250
Minimum warning point of 2250 RPM
….
Warning point can be set in 250 RPM increments
W 9750
Maximum warning point of 9750 RPM
SRV HR
Sets service hour value used when resetting count down service hour meter
OFF
Service hour meter disabled (default)
10
Minimum service hour set point
…
Service hour reset point can be set in 10 hr increments
310
Maximum service hour set point
MAIN
Returns to info menu
GAUGES
Gauge option menu
VLT HI
Set high voltage warning point (default 15.4V)
VLT LO
Set low voltage warning point (default 11.1 V)
FL SND
Set fuel sender used
NONE
No fuel sender used, fuel area will be blanked out (default)
STOCK
Uses stock fuel sender for Rhino
DAKDIG
Uses Dakota Digital sender to be installed in tank
CUSTOM
Uses custom sender, user must calibrate for the sender curve
CAL Y
(
CAL N
)
Select
CAL Y
to calibrate sender
EMPTY
Start with empty tank, or fuel sender in empty position
ADD 33
Fill fuel to 1/3 tank, press right switch to save point
ADD 66
Fill fuel to 2/3 tank, press right switch to save point
ADD 99
Fill fuel to full tank, press right switch to save point
DONE
Custom fuel calibration is complete, press right switch to go back to menu
OIL LO
Set low oil pressure warning point (default 9 PSI)
WTR HI
Set high water temp warning point and set temperature unit (default 230F)
DEG F
(
DEG C
)
Select temp unit, press left switch to change, right switch to save
WTR HI
Select high warning, left switch to change, right switch to save
MAIN
Returns to info menu
OPTION
Option menu
DIM LV
Adjust dimming point on gauge
OFF
Dimming function is off
LVL 1
Gauge will dim when light on gauge face is very low (default)
…
7 selectable dimming levels
LVL 7
Gauge will dim early when more light is on gauge face
DM OUT
Enables/disables dim output for other gauges
ON
Dim output will be high when gauge is dimming
OFF
Dim output will be disabled (default)
WN OUT
Selects which gauges provide a warn out signal on warn out wire (default all on)
WN OUT
Gauges that provide signal out are lit up, left switch to change, right switch to save
NO WRN
Warn output wire is disabled