MAN# 650052
5
SENDER WIRING
GRAY
-
connect to tank pressure sender (optional).
The GRAY wire should be left open if the tank pressure is not being monitored.
Sender Wiring for 4 bag systems:
GREEN
-
connect to the right rear pressure sender.
PURPLE
-
connect to the left rear pressure sender.
ORANGE
-
connect to the right front pressure sender.
BROWN
-
connect to the left front pressure sender.
Sender Wiring for 3 bag systems:
GREEN
-
DO NOT CONNECT.
PURPLE
-
connect to the rear pressure sender.
ORANGE
-
connect to the right front pressure sender.
BROWN
-
connect to the left front pressure sender.
Sender Wiring for 2 bag, front/rear systems:
GREEN
-
DO NOT CONNECT
PURPLE
-
connect to the rear pressure sender.
ORANGE
-
DO NOT CONNECT
BROWN
-
connect to the front pressure sender.
Sender Wiring for 2 bag, left/right systems:
GREEN
-
connect to the right pressure sender.
PURPLE
-
connect to the left pressure sender.
ORANGE
-
DO NOT CONNECT
BROWN
-
DO NOT CONNECT
Sender Wire Connection:
The SEN-03-1 has just a single terminal on top. Connect this to a wire that goes back to
the controller. The sender case is the ground connection. Screw the sender into a grounded
fitting or attach a ground wire to the case.
The SEN-03-5 has two terminals on top. Connect one to a wire that goes back to the
sender input on the controller. Connect the other to a wire that goes back to the ground
connection for the gauge. The polarity of the two wires on the sender does not matter.
Mounting:
The gauge requires a round hole 2-1/16” in diameter. It should be inserted into the
opening from the front and the U-clamp will be installed from the back. Tighten the two nuts on
the U-clamp so that the gauge is secure. Gauge depth to the back of the case is 1”. Gauge
depth including the mounting studs is 1-7/8”.
The controller can be mounted to wood, metal, or plastic using screws with the four
mounting holes, double sided tape, or hook and loop fasteners.