MAN# 650052
3
Setting the sender type:
While the tank sender is always a 400 psi type, the bags will work with either 150 psi
senders or 400 psi senders. The procedure for setting the sender type is as follows:
1. Push and hold in the joystick while you turn the key on. The display should light up and
show “SETUP”.
2. Release the switch. Push the joystick up or down until “SNDER” “TYPE” is displayed.
3. Push in and release the joystick. The display should show “xxx SNDER” “TYPE” where
is xxx is 150 for the 150 psi senders and 400 for 400 psi senders.
4. Each time the joystick is moved up the type will change.
5. When the desired sender type is shown push in and release the joystick.
6. The display will now show “SETUP” “DONE”. Push in and release the joystick to exit
setup or move the joystick down to select a different setup menu.
Setting the warning limit:
The low and high warning limits can be set to different values, also the front bag, rear
bag, and tank warnings can each be set differently. The push button switch on the front of the
display is used for setting the warning limit. The procedure for setting the warning limit is as
follows:
1. Push and hold in the joystick while you turn the key on. The display should light up and
show “SETUP”.
2. Release the switch. Push the joystick up or down until “WARN” “SETUP” is displayed.
3. Push in and release the joystick. The display will now show “xxx FRONT” “HIGH” where
xxx is the current front high pressure warning point.
4. Each time the joystick is moved up the high warning point will increase. When the
joystick is moved down the high warning point will decrease.
5. When the desired high warning point is displayed push in and release the joystick. The
display will change to “ xx FRONT” “LOW ” where xx is the current front low pressure
warning point.
6. Move the joystick up or down to change the low warning values until the desired value is
shown.
7. Push in and release the joystick. The display will change to “xxx REAR” “ HIGH” where
xxx is the current rear high pressure warning point.
8. Move the joystick up or down to change the high warning values until the desired value is
shown.
9. Push in and release the joystick. The display will change to “ xx REAR” “ LOW” where xx
is the current low pressure warning point.
10. Move the joystick up or down to change the low warning values until the desired value is
shown.
11. Push in and release the joystick. The display will change to “xxx TANK” “HIGH” where
xxx is the current high pressure warning point.
12. Move the joystick up or down to change the high warning values until the desired value is
shown.
13. Push in and release the joystick. The display will change to “xxx TANK” “LOW” where xx
is the current low pressure warning point.
14. Move the joystick up or down to change the low warning values until the desired value is
shown.
15. Push in and release the joystick. The display will now show “SETUP” “DONE”. Push in
and release the joystick to exit setup or move the joystick down to select a different setup
menu.