5. Stock 3-Wire alternators will need an additional wiring connection at the gauge cluster connecter.
You will need to add resistance from the Pink/Black wire in the A10 location to the Brown wire in
the A3 location. The range needed is 500-30 ohms, three 1/4W 1K resistors in parallel will be in
range at 333 ohms. The provided alternator load harness can be used to achieve this.
4. Refer to the main manual for wiring instructions and re-install the cluster in reverse order using all