TIMING GEAR TACH INTERFACE UNIT 

SET

TGR 

 
Convert a signal from an engine timing gear-tooth sensor to an ignition tachometer signal. 
 

For using a standard 4-6-8 cylinder tachometer on a diesel engine, the DSL-1 E can convert a 

timing gear sensor signal into an a standard gas ignition signal.  Calibration is accomplished by 
determining the number of teeth on the timing gear or using another tachometer as a reference.  
Consult a vehicle service manual to determine the sensor color code and connection.  The GROUND 
terminal on the DSL-1 E should be connected to a good ground.  The SIGNAL IN terminal will connect 
to the timing gear sensor signal.  Connect the POWER terminal to 12V accessory power.  NORMAL 
terminal will provide the standard signal to the tachometer.  If your tachometer will not read from this 
then try the HI VOLT terminal. 

 S

E

N

S

O

R

 G

N

D

 G

R

O

U

N

D

 P

O

W

E

R

 N

O

R

M

A

L

 H

V

O

L

T

 N

O

T

 U

S

E

D

 S

IG

N

A

L

 I

N

 O

U

T

 3

S

E

T

IN

C

DSL-1 E

+

-

D

IE

S

E

L

 T

A

C

H

 I

N

T

E

R

F

A

C

E

d

a

k

o

ta

d

ig

it

a

l.

c

o

m

12V Accessory Power

GROUND

Sensor ground (not used)

Timing gear signal

standard tach output

1/2 rate tach output

high voltage tach output

jumper to HI VOLT output for some
early Toyota tachometers

 

Calibration 

Adjust with engine running:  To increase the tachometer reading, press and hold the + push 

button switch.  To decrease the tachometer reading, press and hold the - push button switch. 

Preset or adjust:  The calibration value (tooth count) can be set from 1 – 64. 

1.  Begin with the key off.   
2.  Press and hold the SET switch while turning the key on.  The display will show the current version 

code. 

3.  Release the SET switch.  The display will show “

SEt

”. 

4.  Press and release the INC switch until “

tgr

” is displayed, then press and release the SET switch. 

5.  The display will show the tens digit of the currently stored calibration value.  Press and release the 

INC switch to set this from 0-6 for your desired calibration value. 

6.  Press and release the SET switch to move to the ones digit.  Press and release the INC switch 

until your desired value is shown. 

7.  Press and release the SET switch to save the ones digit and finish.   
8.  The display should now show the next menu option, “

SIG

”.  Turn the key off. 

 