VHX Setup:
Using speed from the BIM-01-2
•
Hold the SW1 switch from the instrument system control box while turning the key on. The message display
should show SETUP.
•
Release SW1. The message display should show SETUP SPEED.
•
Press and hold SW1 for at least 3 seconds and then release it. The message display should show SPEED
SENDER.
•
Press and hold SW1 for at least 3 seconds and then release it. The display should show the current setting.
•
Press and release SW1 until SENDER BUS is displayed.
•
Press and hold SW1 until DONE is displayed.
Using RPM from the BIM-01-2
•
Hold the SW1 switch from the instrument system control box while turning the key on. The message display
should show SETUP.
•
Release SW1. Press and release SW1 until SETUP TACH is displayed.
•
Press and hold SW1 for at least 3 seconds and then release it. The display should show TACH ENGINE.
•
Press and hold SW1 for at least 3 seconds and then release it. The display should show the current setting.
•
Press and release SW1 until ENGINE BUS is displayed.
•
Press and hold SW1 until DONE is displayed.
Using engine temperature from the BIM-01-2
•
Hold the SW1 switch from the instrument system control box while turning the key on. The message display
should show SETUP.
•
Release SW1. Press and release SW1 until SETUP WATER is displayed.
•
Press and hold SW1 for at least 3 seconds and then release it. The message display should show WATER
SENDER.
•
Press and hold SW1 for at least 3 seconds and then release it. The display should show the current setting.
•
Press and release SW1 until SENDER BUS F or SENDER BUS C is displayed depending on your unit choice.
•
Press and hold SW1 until DONE is displayed.
Using oil pressure from the BIM-01-2 (if available)
•
Hold the SW1 switch from the instrument system control box while turning the key on. The message display
should show SETUP.
•
Release SW1. Press and release SW1 until SETUP OIL is displayed.
•
Press and hold SW1 for at least 3 seconds and then release it. The message display should show OIL SENDER.
•
Press and hold SW1 for at least 3 seconds and then release it. The display should show the current setting.
•
Press and release SW1 until SENDER BUS is displayed.
•
Press and hold SW1 until DONE is displayed.
Using fuel level from the BIM-01-2 (if available)
•
Hold the SW1 switch from the instrument system control box while turning the key on. The message display
should show SETUP.
•
Release SW1. Press and release SW1 until SETUP FUEL is displayed.
•
Press and hold SW1 for at least 3 seconds and then release it. The message display should show FUEL
SENDER.
•
Press and hold SW1 for at least 3 seconds and then release it. The display should show the current setting.
•
Press and release SW1 until SENDER BUS is displayed.
•
Press and hold SW1 until DONE is displayed.