Zone lights:
The receiver has a red led light for each of the four zones. The lights can be set to blink for every
activation up to ten and then repeat or turn on once for ten seconds when a signal is received.
1. To have the leds flash once for ten seconds push the “C” button (Figure 1-8) for 0.5 seconds and
release. The four leds will flash once and the zone led will turn on for ten seconds when a signal
is received.
2. To have the zone led flash for each signal received (up to ten) and then repeat, press the “C” but-
ton for 0.5 seconds a second time and the four leds will flash twice.
3. To reset the flashing leds press and hold the “C” button for 2 seconds. The four leds will light for
three seconds and the flashing will stop until the next signal is received.
reminder Beep:
The receiver has a reminder beep that can be set to “beep” every 15 minutes after a signal is re-
ceived. The reminder can be set with the “A” button (Figure 1-10).
1. The reminder beep will only sound if the zone light is set to flash (see previous section on Zone
Lights).
2. To activate the reminder beep press and hold the “A” button for 2 seconds. You will hear one
beep.
3. To deactivate the reminder beep press and hold the “A” button for two seconds and you will
hear two beeps.
6
DCR2500 Manual.indd 6
4/6/2010 8:23:35 AM