5
tone, relay and voltage output:
1. Each of the four transmitter zones (selectable by switch 9 & 10) will sound a tone and activate
the corresponding relay on the receiver.
2. The form “C” relays are rated for 24 VDC at 3 Amp maximum current.
3. The 12 VDC output has a maximum current capacity of 400mA. To select the zone(s) that will
activate the 12 VDC output, locate the jumper “J1” (Figure 1-4) and set the jumper to cover both
pins on the selected zones. If the pins are not connected by the jumper, that zone will not activate
the 12VDC output.
4. The relays and voltage can be set to activate for 1 second, 10 seconds, 60 seconds or 10 minutes.
To change the output duration, locate the jumper “J4” (Figure 1-7) and move it to the desired time.
Note: This jumper only changes the duration of the relay activation. The tone will only sound
for several seconds regardless of how the jumper is set.
DCR2500 Manual.indd 5