8
9
How to program the Auto Dialer to give an audible alarm as well as sending a voice
message (factory default is alarm ON):
1. Key in the four digit user password code (factory default 1234.)
2. Press PROGRAM > 1 > ENTER
3. Press
N
(N =
0
for without audible alarm,
1
for with audible alarm)
. Press ENTER.
Quick guide: Press 1 2 3 4 > PROGRAM > 1 > ENTER >
N
> ENTER
How to set the time the alarm will sound on activation (default time is 3 minutes):
1. Key in the four digit user password code (factory default 1234.)
2. Press PROGRAM > 2 > ENTER
3. Press
Time (Time =
1
for one minute,
2
for 2 minutes, etc. up to 99 minutes).
Press ENTER.
Quick guide: Press 1 2 3 4 > PROGRAM > 2 > ENTER >
Time
> ENTER
How to set entry/exit Delay times (default both delay set at 30 seconds):
The entry/exit times are the times the Auto Dialer gives you to enter/exit the area covered
by the system before it arms/alarms. These are pre-set to 30 seconds. You can also change
the timing to instant or 60 seconds.
Entry Delay:
1. Key in the four digit user password code (factory default 1234.)
2. Press PROGRAM > 4 > ENTER
3. Press
N (N =
0
for instant;
3
for 30 seconds;
6
for 60 seconds)
. Press ENTER.
Quick guide: Press 1 2 3 4 > PROGRAM > 4 > ENTER >
N
> ENTER
CAD-03 Kit Manual.indd 9
10/15/2009 10:16:01 AM