Exit Delay:
1. Key in the four digit user password code (factory default 1234.)
2. Press PROGRAM > 5 > ENTER
3. Press
N (N =
0
for instant;
3
for 30 seconds;
6
for 60 seconds;
9
for 90 seconds)
. Press ENTER.
Quick guide: Press 1 2 3 4 > PROGRAM > 5 > ENTER >
N
> ENTER
How to set an entry/exit delay sound (factory setting entry/exit delay with sound):
1. Key in the four digit user password code (factory default 1234.)
2. Press PROGRAM > 7 > ENTER
3. Press
N
(N =
0
without sound;
1
with sound).
Press ENTER.
Quick guide: Press 1 2 3 4 > PROGRAM > 7 > ENTER >
N
> ENTER
How to disable Tamper Function (factory setting Tamper ON):
1. Key in the four digit user password code (factory default 1234.)
2. Press PROGRAM > 8 > ENTER
3. Press
N
(N =
0
without tamper function;
1
with tamper function).
Press ENTER.
Quick guide: Press 1 2 3 4 > PROGRAM > 8 > ENTER >
N
> ENTER
How to program monthly self-test:
(Most SIM cards will be disabled if they are inactive for
too long. To stop this from happening, enable the self test in which the dialer will call and give
an audible beep once a month.)
1. Key in the four digit user password code (factory default 1234.)
2. Press PROGRAM > 0 > ENTER > 2 >ENTER
3. Press
N
(N =
0
to enable test;
1
to disable test).
Press ENTER.
Quick guide: Press 1 2 3 4 > PROGRAM > 0 > ENTER > 2 > ENTER>
N
> ENTER