Installation (continued)
A
remote switch
is
recommended
for
temporarily
shutting
off
the
pump’s operation.
Call
Daken
Product
Support
at
1800 648 384
to
order
Daken
Item
#250555
for
pump
models
D11BP,
D15BP, D20BP
.
Order
Item
#777493
for
pump models
D3BP,
D
5
BP
, D8BP,
and .
3. Connect pump
to battery
Connect the pump to a 12V DC battery using the following procedure:
a)
Disconnect the vehicle battery ground wire.
b)
Connect the pump’s
red
wire to the
positive
(+)
terminal of the battery.
c)
Connect the pump’s
black
wire to the
negative
(-)
terminal of the
battery.
d)
Reconnect the vehicle battery ground wire.
Note:
Skip steps (a) and (d) if battery is not in a vehicle.
WARNING:
Always connect in this sequence to avoid possible shock.
D3BP, D5BP,
D8BP, D11BP,
D15BP, D20BP
Positive
(red wire)
Negative
(black wire)
D26BP
Positive (red)
Negative (black)
4. Disconnect
after use
AFTER EACH USE, disconnect power to the pump
using the following
procedure:
a)
Disconnect the vehicle battery ground wire.
b)
Disconnect the pump’s
black
wire from the
negative
(-)
terminal of
the battery.
c)
Disconnect the pump’s
red
wire from the
positive
(+)
terminal of the
battery.
d)
Reconnect the vehicle battery ground wire.
Note:
Skip steps (a) and (d) if battery is not in a vehicle.
WARNING:
Always disconnect in this sequence to avoid possible shock.
NOTE: It is important to disconnect power to the pump when not in use for
safety reasons. ALWAYS verify that the power has been disconnected
before adding chemicals or servicing.