2
. Terms and Symbols12
2. Terms and Symbols
2.1 Terms
- The terms used in this User’s Manual is explained below.
- The terminology described below is limited to this User’s Manual and note that it may be
different from those generally used.
(1) Electro Surgical Unit (ESU)
- The ESU is a medical device that generates high-frequency current applied to body organs
to generate heat used for cutting and coagulation.
(2) Cutting or Cut
- It is a phenomenon of destroying cells by the heat (more than 100
℃
) that is produced as
applying the high-frequency current from the ESU to tissue.
(3) Coagulation (Coag. Or Co.) .
- It is a phenomenon that moisture in the cells dries off by the heat (60
~
90
℃
) produced
when the high-frequency current generated by the ESU is applied to an organ of the
human body.
(4) Bi-polar cutting output
- It is the output from the bipolar output jack when bipolar cut mode used.
(5) Bi-polar coagulation output
- It is the output from the bipolar output jack when bipolar coag. mode used.
(6) Mono-polar cutting output
- It is the output from the mono-polar output jack when pure mode or blend mode used.
(7) Mono-polar coagulation output
- It is the output from the mono-polar output jack when contact mode or spray mode used.
(8) D.R.M (Daiwha Return electrode Monitor)
- As a more advanced safety system than the old Return Electrode Alarm, D.R.M can avoid
the potential burn damage which may result from the little contact area of dual pad by grace
of its monitoring function.
(9) Active electrode
- It’s an electrode of the metal material that is connected to the terminal of the handle.
- It becomes the path by which the high-frequency current from the mono-polar output jack is
applied to the human body.
- Depending on the usage, a variety of shapes such as lancet, loop, needle, etc. are offered.
(10) Return electrode
- It is the electrode to return to the device the high-frequency current that is applied to the
human body through the active electrode.
- In general, it is called as ‘neutral plate’, patient plate, or pad. It designates the electrodes
connected to the neutral plate outlet.
※
Applied Parts : electode tip, neutral pad
Содержание Meditom DT-400S
Страница 29: ...5 Connecting Accessories with the unit29 5 3 Bipolar Forceps 5 4 Foot switches ...
Страница 40: ...9 Load Regulation Vpeak Graphs40 9 1 2Open Circuit Peak Voltage ...
Страница 41: ...9 Load Regulation Vpeak Graphs41 9 2 Blend1 Cutting Mode 9 2 1Load Regulation DT 400S DT 300S ...
Страница 42: ...9 Load Regulation Vpeak Graphs42 9 2 2Open Circuit Peak Voltage ...
Страница 43: ...9 Load Regulation Vpeak Graphs43 9 3 Blend2 Cutting Mode 9 3 1Load Regulation DT 400S DT 300S ...
Страница 44: ...9 Load Regulation Vpeak Graphs44 9 3 2Open Circuit Peak Voltage ...
Страница 45: ...9 Load Regulation Vpeak Graphs45 9 4 Blend3 Cutting Mode 9 4 1Load Regulation DT 400S DT 300S ...
Страница 46: ...9 Load Regulation Vpeak Graphs46 9 4 2Open Circuit Peak Voltage ...
Страница 47: ...9 Load Regulation Vpeak Graphs47 9 5 Forced Soft Coagulation Mode 9 5 1Load Regulation DT 400S DT 300S ...
Страница 48: ...9 Load Regulation Vpeak Graphs48 9 5 2Open Circuit Peak Voltage ...